If, during the start phase, no flame generation can be achieved or the required temperature at the “flame temperature
sensor” cannot be reached, a switch-off process is initiated.
10.2. Heating mode
After the positive conclusion of the “Start phase”, the stove automatically switches to “Heating mode”.
In “Heating mode”, the heat output of the stove is adjusted in modular fashion to the room temperature or to the
difference between the ACTUAL and TARGET room temperatures.
If the difference between the ACTUAL and TARGET room temperatures is big, then the stove heats with a bigger
heat output.
The nearer the ACTUAL and TARGET room temperatures get to each other, the more the stove's heat output is
reduced.
10.3. Burner test (burner cleaning)
During the “Heating mode” operating status, an automatic burner cleaning process is carried out at regular time
intervals (e.g. 30 minutes).
This process takes approx. 2 minutes.
10.4. Cooling down
If the set TARGET room temperature is reached or the ON/OFF” button is pressed, then the operating status
switches to “Cooling down”.
The cooling down phase is restricted by timing control (duration about 15 minutes).
After the end of the “Cooling down” operating status, the appliance switches to “Standby” operating status or “OFF”.
10.5. ECO mode
Eco mode means continuous operation at a low output, if the “ACTUAL room temperature” is higher than the set
“TARGET room temperature” i.e. the stove does not switch off but continues to run on a “smaller flame”.
If the set “TARGET room temperature” is exceeded by more than 2°C in eco mode despite a small flame,
eco mode is automatically switched off and the stove switches to the “Cooling down” operating status.
Eco mode function is automatically deactivated.
If an “ACTUAL room temperature” of 30°C is exceeded in eco mode,
eco mode is automatically switched off and the stove switches to the “Cooling down” operating status.
Eco mode function is automatically deactivated.
10.6. Standby
The stove is in a waiting position
Before the stove can switch from “Standby” back to the “Start zone 1-20” operating status, two start conditions must
be fulfilled:
The ACTUAL room temperature must be at least 1.0 °C below the set TARGET room temperature
The flue gas temperature measured with the flue gas thermosensor must be less than 70 °C
10.7. Switch-off
If a fault occurs, then a switch-off is initiated. The components are switched on or off as follows:
Induced draught fan ON
Screw conveyor OFF
Ignition OFF
15


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Haas-Sohn HSP 2.17 HOME at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Haas-Sohn HSP 2.17 HOME in the language / languages: English as an attachment in your email.

The manual is 0.59 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Haas-Sohn HSP 2.17 HOME

Haas-Sohn HSP 2.17 HOME User Manual - German - 16 pages

Haas-Sohn HSP 2.17 HOME User Manual - French - 22 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info