Table of Contents
1. Description 3
2. General Information, Safety Information 3
3. Installation of the pellet stove and
connection to the chimney 5
4. The functional features of the pellet stove 7
5. Operating states of the pellet stove: 7
5.1. Measurement – degree of soiling of burner
tray before the start phase 7
5.2. Start phase 7
5.3. Heating Mode 8
5.4. Measurement – Degree of soiling of burner
tray during the heating operation 8
5.5. Cooling 9
5.6. Standby 9
5.7. Safety shutdown 9
5.8. Fault 9
5.9. Shutdown – Operating State OFF 9
5.10. Power failure 10
5.11. Overheating 10
5.12. Low-temperature shutdown 10
6. Description of keys on the control unit 10
6.1. Control unit 10
6.2. Information pages 11
6.2.1 Info page 1 (default page) 11
6.2.2 Main menu 11
6.2.3 Setting the Mode 11
6.2.4 Setting the time and date 11
6.2.5 Setting the times and target room
temperatures for automatic mode 12
6.2.6 Setting the target room temperature for
heating mode 12
6.2.7 Fault page 12
6.3 Language Setting 12
6.4 Description – Heating Curve 12
6.5 Description - GSM Operation 12
6.5.1 Description – Operator Telephone Number13
6.5.2 Description - GSM Info Page 13
6.6 Description – Key Lock (child safety device) 13
7. Operation of the pellet stove 13
7.1. Fuel 13
7.2. First commissioning of your pellet stove 14
7.3. Selection of operating mode 15
7.3.1 Mode „Heating“ 15
7.3.2 Setting the target room temperature in
mode „Heating“ 15
7.3.3 Mode „Auto“ (Weekly program) 15
7.3.3.1 Setting date and time 15
7.3.3.2 Mode „Auto“ (Weekly program) 15
7.3.3.3 Setting the target room temperature in
mode „Auto“ (weekly program) 15
7.3.3.4 Programming example for the weekday
Monday“ 16
8. Cleaning and maintenance work 16
8.1 Cleaning the top surface 16
8.2 Cleaning the glass panel 16
8.3 Cleaning the burner pot 16
8.4 Removing ash from the furnace 17
8.5 Cleaning the pellet tank 18
8.6 Cleaning the flue-gas draughts and the smoke
pipes 18
8.7 Cleaning the flue-gas housing and ventilator 18
8.8 Cleaning the air filter 19
9. Description of the components 19
9.1 Storage container (Pellet tank) 19
9.2 Worm motor / Screw conveyor 19
9.3 Burner pot with burner wedge: 19
9.4 Electrical ignition 20
9.5 Ash tray 20
9.6 Convection air blower with rotational speed
feedback 20
9.7 Controller 20
9.8 Control unit 21
9.8.1 Background lighting 21
9.8.2 Activation of the background lighting 21
9.9 Induced draught blower with rotational speed
feedback 22
9.10 Flame- or furnace temperature sensor
(Temperature sensor Furnace) 22
9.11 Air volume sensor – flow measuring transducer
22
9.12 Temperature sensor Waste-Gas 22
9.13 Room temperature sensor 22
9.14 STB – Safety Temperature Limiter 22
9.15 Furnace lining 22
9.16 Optical visualization of the burner soiling by
means of three different-colored light-
emitting diodes – similar to a “traffic light
control“ 23
9.17 Smoke pipe connection 23
9.18 Mains cable and main switch 23
10.1 Parts list 24
10.2 Assembly instructions GSM Module 24
10.3 GSM Module Setup 24
10.4 Technical Specifications of the GSM Module
25
11. Technical Specifications 26
12. Faults, Causes, Remedy 27
13. Name plate 32
14. Spare parts list 33
15. Wiring Diagram 37
16. Guarantee 39
2


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Haas-Sohn ECO-PELLET at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Haas-Sohn ECO-PELLET in the language / languages: English as an attachment in your email.

The manual is 3.71 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Haas-Sohn ECO-PELLET

Haas-Sohn ECO-PELLET User Manual - German - 43 pages

Haas-Sohn ECO-PELLET User Manual - French - 40 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info