Description of the system for supplying the air needed for combustion:
The system for supplying the air needed for combustion in stove unit type Esprit 185.16/3-AL has three settings:
the primary air is adjusted by means of the air intake control(11) With the handle in position 2 (‘right’) the
primary air
I enters through the grate, and the primary air II enters through that area of the combustion chamber which is to
wards the front of the stove. With the handle in position 1 (‘middle’) the primary air I only enters via the grate.
The amount of secondary air is set at an optimum level for the unit to provide the necessary ventilation to keep
the window clean and to provide the necessary air for secondary combustion; it is permanently adjusted for
increased comfort. The pre-heated secondary air flows past the top end of the inspection window (8).
Air intake control Primary air I Primary air II Use:
"right" open open
For use when it is heating up and after fuel has been
added
"middle" shut open In normal operation
"left" shut shut Only for keeping the embers glowing
Connection for providing the air needed for combustion:
In airtight buildings there can be reduction in the oxygen content of the room in which the stove is set up; it must
therefore be ensured that there is adequate ventilation. The stove unit type Esprit 185.16/3-AL therefore offers
you the possibility of drawing in the air needed for combustion from outside. The stove can then be operated
without having to depend on the air within the room. In order to do this the air from outside that is needed for
combustion is supplied by means of a flexible pipe attached to the socket for the pipe (16). It is possible for you to
change the position of the pipe socket to the left, right or rear of the stove unit. The end of the pipe carrying the
air must be located in the open air, or in a well ventilated room situated within the building
Fuels Amount of fuel Primary air:
air intake control Secondary air
(not adjustable)
Chopped
wood
Wood
briquettes:
2 to 3 pieces of
wood (approx. 2 to 2.5kg)
or 1 wood briquette (2kg)
For approximately 10 minutes: open
(handle to the right),
then operate with the handle in
the middle position
open
Tip for burning wood: Every time the stove is lit leave the appliance in the ‘right’ position
until the fuel is burning well (around 10 minutes). (This time can vary somewhat depending
on the amount of draught and the pressures involved).When adding fuel shut the air intake
as indicated.
Specification plate:
Nennwärmeleistung
Zugelassener Brennstoff:
Prüf Nr. TGM HL 6220 / RRF-29 11 2643
Staub bez.auf 13% O
2:
21mg/Nm3 Wirkungsgrad: 80,4% CO:0,03%
HAAS + SOHN OFENTECHNIK GMBH
URSTEIN NORD 67 A-5412 PUCH
Kamineinsatz Bauart : EN 13229-W
Typenbezeichnung: Esprit 185.16-AL
Herstellnummer: 11 06 000085
Wärmeleistungsbereich: 3,4 -7,5kW
7,0 kW
Holz, Holzbrikett nach -DIN 51731,
Lesen und befolgen Sie die Bedieungsanleitung!
Mehrfachbelegung des Schornsteins ist zulässig
Zeitbrandfeuerstätte
Prüf. Nr.
Kamineinsatz Esprit 185.16-AL, Variante Esprit 185.16/4-AL / DIN EN 13229
Rhein Ruhr Feuerstättenprüfstelle Oberhausen RRF-29 11 2643
Kaminbausätze: EN13240
Kaminöfen: Provence, Dijon, Bari, Cilento, Roma RRF-40 04 632
Kaminöfen: Elsass, Rhone, Sylt RRF-40 04 632
Kaminofen: Ascim RRF-40 11 2667
18


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Haas-Sohn Dachstein at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Haas-Sohn Dachstein in the language / languages: English as an attachment in your email.

The manual is 1.72 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Haas-Sohn Dachstein

Haas-Sohn Dachstein Installation Guide - German - 20 pages

Haas-Sohn Dachstein Installation Guide - French - 20 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info