3.2. Safe distance between the fireplace stove and flammable
material
If you have installed the fireplace stove within the room with flammable objects,
flammability Class B, C1 and C2, the safety distance from the front (or side glass surfaces)
is 800 mm; for the other directions, the safety distance is 200 mm. If the fireplace stove is
installed within a room with flammable objects, flammability class C3, the safety distances
must be doubled. Kindly pay attention to the information provided in Supplement 1. The
most important installation dimensions are shown in the product name plate.
3.3. Safe distance between the smoke flue and flammable material
The safety distance from the door frame lining and similar constructions made of flammable
materials and from pipeline installations, incl. insulating elements is 200 mm (minimum).
The safety distance from the other parts of the constructions made of flammable materials
is minimum 400 mm. This is applied to building materials, flammable Class B, C1 and C2
(see Chart 3). Kindly pay attention to the information provided in Supplement 2. More
accurate classification is available only if testing is performed for the particular product.
3.4. Directions for safe operation
For firing or kindling, never use any flammable liquid! It is forbidden to burn any plastic
material, wooden material combined with chemicals (chipboard, etc.) or domestic
(unsorted) refuse containing plastic, etc.
The fireplace stove must be operated by adults only! Never allow children in the
room unattended. The surface of the fireplace stove is overheated, especially the
glassy components: any contact will cause serious burnt. During the operation,
occasional monitoring is required. For safe operation and handling the regulation elements
and the door closing devices, use the protective glove (a part of the supply).
Do not put any objects or tools on the fireplace stove while in operation or hot: flammable
material may cause fire. Do not put any vessels with cold liquid in the ceramic tiled
fireplace stove while hot: the tiles might crack!
The ashpan must be manipulated with utmost care. The ash may be very hot so there is
danger of serious burnt. Hot ash must not be in contact with flammable material for
example, while pouring it into waste container.
The fireplace stove must be operated in compliance with the directions and
recommendations in the Operating Instructions. It is forbidden to modify the
fireplace stove in any way unless approved by the manufacturer.
Flammability class: selected building materials
Building materials and
products
Building materials
A – Flame proof matter Granite, sandstone, heavy concrete (porous), brick,
ceramic tiles, special plaster
B - heavy fuels Akumin, Heraklit, Lignos, Itaver
C1 – hardly inflammable Hardwoods, Hobrex panels, Sirkolit, hardened paper,
umakart
C2 – medium inflammable Chip boards, Solodur, cork parquet, rubber, floor covering
C3 - Flash fuels Wood-fibre boards, polystyrene, polyurethane
Chart 3
4. INSTALLATION AND CONNECTION TO THE CHIMNEY
Caution! For installation, relevant local regulations must be strictly adhered,
including the regulations related to national and European standards for this type of
device.
4.1. Connection to the chimney or chimney insert
Connection of the fireplace stove to the chimney vent is subjected to approval by specialist
chimney company (CSN 73 4201:2008), or to approval according to relevant regulations in
force in the country where the installation is made. Kindly pay attention to the information
provided in Supplement 2.
To provide proper function and operation, proper chimney effect in the smoke flue
neck is required. For the minimum stack draught, see the Technical Card for the particular
product. Insufficient chimney effect results in malfunction of the fireplace stove, excessive
dirt on the glass, and excessive clogging in the smoke flue system. The general heat
capacity of the device is reduced. If you feed the fire while proper chimney draught is not
provided, flue gases may spread throughout the room. For this reason, it is strictly
recommended to have regular check done by a specialist chimney company and maintain
the heating device regularly. If the chimney effect is too high over 20 Pa it is recommended
to install a suitable blocking device (for example, flue tube with a block). Excessive chimney
draught may cause troublesome operation, for example, too intensive burning, high fuel
consumption, damage on the heating device, etc.
Caution! It is recommended to connect the fireplace stove with rear outlet to the
chimney by direct connection (without an elbow element). Any other method of the
connection should be approved by a specialist chimney company.
4.2 Connecting the stove fireplase to the venting unit
It is recommended to connect the stove (insert) to a separate chimney vent. A joint
chimney vent may be used for the connection only if the safety regulations valid in the
country of installation allow doing so. It is forbidden to connect the stove (stove insert) to
the same vent used for a gas appliance. The minimum working height of the vent is 5 m.
Depending on local conditions, it is possible to connect the stove in the vent with a
working height under 5 m providing that the flue way calculation demonstrates that such a
height is satisfactory.
Caution! (Provisions CSN 73 42 01: 2008)
The smoke flue vent diameter must not exceed the diameter of the chimney vent; it must
not be narrowed towards the chimney, either. If the calculation demonstrates that the vent
diameter of the smoke flue and chimney can be smaller than the flue neck diameter of the
device, the diameter of the smoke flue will be reduced just after the flue neck of the
device, by means of a short transition or abrupt.
4.3. Directions for smoke flue installation and safety
Connect the smoke outlet neck with the chimney in the shortest possible way so that the
length of the smoke path is no longer than 1.5 m. The smoke pipes and the elbow piece
must be tightly connected, overlapping at least 60 mm. Pay special attention to the fact that
the joints must agree with the flue outflow. The joint between the smoke flue and the smoke
outlet neck must be drilled together and fixed with a rivet or pin; the same is applied for the
smoke pipes and the elbow. The hole (entrance point) in the chimney must be provided
with a metal stress ring (proper diameter). The smoke flue should ascent towards the
smoke uptake at angle approx. 10°.
7
8 9
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Haas-Sohn ANDRUS at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Haas-Sohn ANDRUS in the language / languages: English as an attachment in your email.

The manual is 0,31 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Haas-Sohn ANDRUS

Haas-Sohn ANDRUS User Manual - German - 7 pages

Haas-Sohn ANDRUS User Manual - French - 7 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info