6
Ignition Heating Shut input of air
WARNING
During the operation regime of heating, the lever must not be set to "Shut input of air" "0"; it could bring about
a sudden inflammation of fuel.
5.4.2. Ignition without the air control EASY CONTROL
First, insert chunks onto the bottom of combustion chamber or onto the grid, by size (approx. 1.5 to 2.0 kg).
Then, put a solid fire-lighter cube on the chunks, and a small amount of fine wood onto the top. The above
mentioned amount of the wood is ONLY for heating.
All air slide valves (primary and secondary air regulators) must be fully opened. After flooding, the
combustion chamber door must be closed. The heating process depends on the draft of the chimney. Once
the complete fuel starts to burn, the "Primary Air Regulator" slide valve must be closed.
Combustion air
1- Primary air controller
2- Secondary air controller
3- Tertiary air
5.5. Stoking of fuel
The fuel should be laid on live embers only (without flame).
5.5.1. Chimney stove with EASY CONTROL
Before opening the door of the fire box, the lever should be brought to the position "Input of air closed" 0", in
order to avoid the escape of combustion products to the living room.
After stoking of fuel, close the door of the fire box again.
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Haas-Sohn AARHUS-III at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Haas-Sohn AARHUS-III in the language / languages: English as an attachment in your email.

The manual is 2.8 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Haas-Sohn AARHUS-III

Haas-Sohn AARHUS-III User Manual - French - 16 pages

Haas-Sohn AARHUS-III User Manual - French - 16 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info