665707
14
Zoom out
Zoom in
Previous page
1/56
Next page
14
TIG 160 DC LIFT
MADE IN FRANCE
EN
TIG WELDING (TIG LIFT MODE)
The DC TIG welding requires a protective gas (argon).
Follow the steps below:
1. Connect the earth clamp to the positive socket (+).
2. Connect the torch to the negative socket (-), the DINSE connector and the gas connector.
3. Connect the gas pipe from the rear of the welder to the owmeter of the gas cylinder
4. Select TIG mode (3) using the selector button (5), press until the TIG indicator illuminates
.
5. Adjust the desired current (display(1)) using the keys (4), according to the thickness of the metal workpiece (30A /
mm).
6. Set the gas ow on owmeter.
7. To start
a- Touch the electrode on the welding workpiece.
b- Raise the electrode to between 2 - 5 mm from the workpiece.
8. When nished : Release the trigger, downslope, post-gas.
Adjustment of downslope
Function activation:
This function allows the user to adjust the time required at the end of welding for the gradual decline in the welding
current until the arc stops. This function helps to avoid cracks and craters at end of welding.
To activate it, proceed as follows:
1- Press the selector button (5) for 3 seconds
2- The TIG indicator starts ashing and the display indicates the current downslope time
3- Set the automatic arc downslope you wish from 0 to 10 sec (display(1)) using key (4).
4- Validate your choice pressing button (5). The TIG indicator remains illuminated.
Recommended combinations / Electrode grinding
Current (A)
Ø Electrode (mm)
= Ø wire (ller metal)
Ø Nozzle (mm)
Flow rate
(Argon L/mn)
0,5-5 10-130 1,6 9,8 6-7
4-7 130-160 2,4 11 7-8
To optimise the welding process, it is recommended to grind the electrode prior to welding as described in
the diagram below:
L = 3 x d for a low current
L = d for a strong current
L
d
14


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gys TIG 160 DC LIFT at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gys TIG 160 DC LIFT in the language / languages: English, German, Dutch, French, Italian, Spanish as an attachment in your email.

The manual is 2,34 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info