TCB 60 / TCB 90 / TCB 120
GENERAL DESCRIPTION
Congratulations for the selection of this product, which has been designed with great care. To
get the best use of it, please read carefully the following instructions. Keep this instruction
manual safe, you may want to read it again later.
The chargers TCB 60, TCB 90 and TCB 120 are designed to charge lead acid batteries with
liquid or gel electrolyte, nominal voltage from 12V, and with capacity according to the following
table:
minimum
maximum
TCB 60 15 Ah 60 Ah
TCB 90 15 Ah 90 Ah
TCB 120 30 Ah 120 Ah
OPERATING MODE WITH TESTER FUNCTION
When it is not connected to the mains supply, this charger is a battery tester. It lets you know
the state of the battery. The integrated voltmeter informs you by three LEDs:
red : <12.3V : battery to be charged
orange : between 12.3 and 12.6V : middle charge
green : >12.6V : charged
CONNECTION IN CHARGER FUNCTION
Preliminary precautions
For indoor use, with good ventilation.
Remove the battery caps if there is, and check the level of liquid. If it is not correct, filled up
with distilled water. Clean well the battery terminals.
Check if the battery capacity and voltage are compatible with your charger.
Connection and disconnection
Connect the clamps (+ red, - black) to + and - battery terminals, making sure you get a good
electric contact, respecting the following order.
Connect first the battery terminal not connected to the chassis of the vehicle.
Then connect the other connection to the chassis remote from the battery and any
fuel line.
Select the charge speed with the front switch
At last, plug in your charger to 230 V 50/60 Hz mains supply.
After charging, disconnected the battery charger from supply mains. Then remove the chassis
connection and the battery connection, in this order.
Charge process
The green light "POWER" above the fuse indicates AC power connection.
The orange light indicates that the charge is in progress.
The green LED lights when the charge is finished.
If the green LED is not lighting after quite a long time, check the front fuse after switching off
your product. If it still does not work, please check the battery by a professional.
This product can charge automatically one battery with its rated loading current, and then
continue with a moderate speed to finish the loading 100%. With that function « floating »,
you can leave the battery connected to your product unlimitedly without any risk.
The charger detects a battery with a voltage above 4 V.
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gys TCB-120 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gys TCB-120 in the language / languages: English, German, French, Spanish as an attachment in your email.

The manual is 0,37 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info