665755
11
Zoom out
Zoom in
Previous page
1/52
Next page
11
M1 - T1 & M3 - T3 GYS AUTO
EN
CHOICE OF REELS
Possible settings :
type l
Torche 1
T1,T3,M1,M3
Torche 2
T3/M3
Spool gun
T1/T3/M1/M3
Gaz
acier
Ø 300 x
argon
+
CO2
Ø 200 x x
Ø 100 x
inox
Ø 200 x x
Ø 100 x
CuSi3 Ø 200 x x
argon
pur
CuAl8 Ø 200 x x
Alu
AlMg5
Ø 300 x*
Ø 200 x* x*
AlSi5 Ø 100 x
AlSi12 Ø 100 x
CuSi3: Recommandation OPEL & MERCEDES
CuAl8: Recommandation Peugeot/Citroën/Renault
AlSi12: Recommendation for automotive aluminium from metal sheet of 0,6mm to 1,5 mm of thickness.
* Consider Teon sheath and special aluminium contact tip
«MANUAL» MODE (FIG 5)
1-welding mode choice :
- Normal (2T) : standard two-stage welding
- Delay: intermittent welding modes for an optimised
operating procedure.
- Spot:spotwelding with ajustable spot diameter
2- Wire speed settings : wire speed tting potentiometer.
The speed varies from 1 to 15L/minute.
3- Spot/delay potentiometer tting
4- Manual mode : In manual mode, the wire speed is
determinated by the user by adjusting the potentiometer
(2).
5- Synergic mode: position the potentiometer (2) in the
middle of the «optimal synergic» zone. In this mode, the
device determines the optimal wire speed according to 3
parameters :
- Voltage
- Wire diameter
- The power mode.
It’s possible to adjust the wire speed +/-.
In position Normal(2T), 2 modes are proposed to ease
the settings of the device: Manual or Synergic.
6- thermal protection light : informs when a short break
is necessary following intensive use.
«MANUAL» MODE (FIG 5)
To set your device, proceed as follow:
- Choose the welding voltage using the 7 positions switch
Example: position 1 for 0,6mm metal sheets and position 7 for 4 mm metal sheets.
- Adjust the wire speed with the potentiometer(2).
Advice:
The wire speed adjustment is often determinated « with the noise »: the arc must be stable and have a low
crackling. If the speed is too low, the arc is not continuous. If the speed is too high, the arc crackles and the wire
pushes back the torch.
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gys T1 GYS AUTO at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gys T1 GYS AUTO in the language / languages: English, German, Dutch, French, Italian, Spanish as an attachment in your email.

The manual is 1,86 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info