200E FV CEL
EN
FIRE AND EXPLOSIONS RISKS
Protect the entire welding area. Compressed gas containers and other inammable material must be
moved to a minimum safe distance of 11 meters.
A re extinguisher must be readily available at all times.
Be careful of spatter and sparks, even through cracks.
They can be the source of a re or an explosion.
Keep people, ammable objects and containers under pressure at a safe distance.
Welding of sealed containers or closed pipes should not be undertaken, and if opened, the operator must remove any
inammable or explosive materials (oil, petrol, gas...).
Grinding operations should not be directed towards the device itself or any ammable materials.
GAS BOTTLE
Gas leaking from the cylinder can create a hazard if present in high concentrations around the work
area.
Transport must be done safely: Cylinders closed and product off. Always keep cylinders in an upright
position securely chained to a xed support or trolley.
Gas cylinders must be stored in an open or ventilated area. The cylinders must be in a vertical position secured to
a support or trolley. Close the bottle after any welding operation. Be careful with gas bottles placed in areas of high
temperature, or in sunlight. Cylinders should be located away from areas where they may be struck or subjected to
physical damage. Always keep gas bottles at a safe distance from arc welding or cutting operations, and any source of
heat, sparks or ame.
Be careful when opening the valve on the gas bottle, it is necessary to remove the tip of the valve and make sure the
gas meets your welding requirements.
ELECTRIC SAFETY
The machine must be connected to an earthed electrical supply. Use the recommended fuse size.
An electrical discharge can directly or indirectly cause serious accidents, or death .
Never touch live parts inside or outside of the device when it is powered on (Torches, clamps, cables, electrodes) as they
are connected to the welding circuit.
Before opening the device, it is imperative to disconnect it from the electrical supply and wait 2 minutes so that all the
capacitors are discharged.
Do not touch the torch or electrode holder and earth clamp at the same time.
Be sure to change the cables and torches if they are damaged, to be performed by qualied and authorized personnel.
Ces accessoires doivent correspondre à la machine (taille, puissance...)
Always wear dry clothes in good condition, in order to be insulated from the electrical circuit. Wear insulating shoes,
regardless of the environment in which you work in.
EMC CLASSIFICATION
These Class A devices are not intended to be used on a residential site where the electric current is
supplied by the public network, with a low voltage power supply. There may be potential difculties in
ensuring electromagnetic compatibility on these sites, because of the interferences, as well as radio
frequencies.
This equipment complies with IEC 61000-3-12.
ELECTROMAGNETIC INTERFERENCES
The electric currents owing through a conductor cause electrical and magnetic elds (EMF). All wel-
ders should use the following guidelines to minimize exposure to the welding circuit’s electromagnetic
elds:
The EMF elds may disrupt some medical implants, such as pacemakers. Protection measures should
be taken for people wearing medical implants. For example, access restrictions for passers-by or an
individual risk evaluation for the welders.
All welders should take the following precautions in order to minimise exposure to the electromagnetic elds (EMF)
generated by the welding circuit::
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gys PROGYS 200E FV CEL at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gys PROGYS 200E FV CEL in the language / languages: English, German, Dutch, French, Italian, Spanish as an attachment in your email.

The manual is 2,24 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info