NEOPULSE 270-T1 / 270-T2 / 300
EN
SEMI-AUTOMATIC WELDING WITH CUSI AND CUAL WIRE (BRAZING MODE)
The NEOPULSE can weld with CuSi and CuAl wire of 0.8/1.
The same as with steel, the capillary tube must be connected and a torch with a steel liner must be used.
In brazing mode the operator must use pure argon (Ar).
REEL AND TORCH ASSEMBLY
• Remove the nozzle (g F) and the contact tube (g E). Open the door of the NEOPULSE.
Fig A:
• Position the wire reel on the support:
- Pay attention to the driving pin when positioning the reel. To set up a wire reel of 200mm, tighten the wire reel to
maximum.
Adjust the brake (2) to avoid reel movement tangling the wire when welding stops. Be careful not to tighten too much.
Fig B:
The drive rollers included have 2 grooves (0.8 and 1.0). The visible diameter indicated on the roller when tted in
place is the diameter currently in use (ie. 0.8mm is visible for use with 0.8mm wire). To weld aluminium or gasless wire,
use the appropriate drive rollers.
Fig C:
To select the adjustment of the drive rollers
• Loosen the drive roller knob (4) as far as possible and insert the wire, tighten the knob again slightly
• Start the motor by pressing the trigger of the torch
• Tighten the knob whilst pressing the trigger until the wire starts to move.
Nb: When welding with Aluminium, use the minimum possible pressure to avoid crushing the wire
• Let about 5cm of wire out of the torch, then put the contact tube (g. E), and the nozzle (g. F) adapted to the wire
to be used at the extremity
Remarks:
• A narrow liner may result in issues causing the wire feeder to overheat.
• The torch connection must be tightened propertly to avoid overheating.
• Check the wire and the reel are not in contact with the body of the welding equipment to avoid any short circuit.
GAS COUPLING
The NEOPULSE is equipped with a quick connector. Use the adapter supplied with the machine. This machine can be
tted with a Ø 200mm or 300 mm reel.
CONTROL BOARD
- A: The navigation in the top menu must be done with the left button. The selection/ validation by push the same button.
- B: The navigation in the bottom menu must be done with the right button. The selection/ validation by push the same button.
- The unlock code is: 0000
- To update the welding parameters, insert the SD card and stop then start the machine.
- A full reset of the machine can be done in option menu, the process requires 1 minute and the SD card.
1 - Welding settings selection
SYNERGIC or MANUAL
2 - Welding process selection
PULSE or STANDARD
3 - Selection of the metal (synergic welding settings)
Each material is associated with a different recommendation for gas and
diameter of wire.
The different materials available are:
- Fe - Steel with Ar+CO2 gas (18%) or CO2 gas (only standard)
- AlMg5 - Aluminium with Ar gas
- SS – Stainless steel with Ar+CO² (2%)
- CuSi – Cu Si 3 with Ar gas
- CuAl – Cu Al 8 with Ar gas
- AlSi 5 and AlSi 12 with Ar gas
For optimal use, it is recommended to use the wire and gas recommended for the selected material.
These synergies modes can be updated by using the SD card (see SD section)
20


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gys NEOPULSE 270-T2 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gys NEOPULSE 270-T2 in the language / languages: English, German, French as an attachment in your email.

The manual is 5,19 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info