NEOPULSE 270-T1 / 270-T2 / 300
EN
Do not point the torch towards any part of the body when the wire feeder is working - the wire can cause injuries when
exiting the torch.
CAUTION: the workpiece can still be hot after welding has nished and can cause burns if handled.
The user must ensure that the torch has sufciently cooled down before starting any cleaning operation. A cool-down
period of 10 minutes after each welding operation is required. When working with a water cooled torch, make sure that
the water cooling system is on to avoid any burns caused by the liquid.
ALWAYS ensure the working area is left as safe and secure as possible to prevent damage or accidents.
WELDING FUMES AND GAS
The fumes, gases and dust produced during welding are hazardous. It is mandatory to ensure adequate ventilation and/
or extraction to keep fumes and gases away from the work area. An air fed helmet is recommended in cases of insuf-
cient air supply in the workplace. Check that the air intake is in compliance with safety standards.
Care must be taken when welding in small areas, and the operator will need supervision from a safe distance.
Welding certain pieces of metal containing lead, cadmium, zinc, mercury or beryllium can be extremely toxic. The user
will also need to degrease the workpiece before welding.
Gas cylinders must be stored in an open or ventilated area. The cylinders must be in a vertical position secured to a
support or trolley.
Do not weld in areas where grease or paint are stored.
FIRE AND EXPLOSION RISKS
Protect the entire welding area.
Compressed gas containers and other inammable material must be moved to a minimum safe distance of 11 meters.
Welding of sealed containers or closed pipes should not be undertaken, and if opened, the operator must remove any
inammable or explosive materials (oil, petrol, gas...). A re extinguisher must be readily available.
Be careful - spatter and sparks can create re or explosion.
Grinding work must not be carried out close to this welding equipment.
GAS CYLINDERS
Gas leaking from the cylinder can create a hazard if present in high concentrations around the work area.
Always keep cylinders in an upright position securely chained to a xed support or trolley.
Close the bottle after any welding operation. Be careful with gas bottles placed in areas of high temperature, or in sun-
light.
Cylinders should be located away from areas where they may be struck or subjected to physical damage. Always keep
gas bottles at a safe distance from arc welding or cutting operations, and any source of heat, sparks or ame.
Be careful when opening the valve on the gas bottle, it is necessary to remove the tip of the valve and make sure the
gas meets your welding requirements.
ELECTRICAL SAFETY
The machine must be connected to an earthed electrical supply. Use the recommended size of fuse.
An electrical shock can cause severe injuries or even death directly or indirectly.
DO NOT TOUCH any LIVE part of the machine (inside or outside) when it is plugged in (Torches, earth cable, cables,
electrodes, wires, rollers, reels) because they are connected to the welding circuit
ALWAYS unplug the machine and wait for 2 minutes before opening the machine - this allows the capacitors to discharge.
Never weld in rain or on a wet surface. The electrical cables must never be in contact with liquid.
Do not touch the torch and earth cable at the same time.
Damaged cables and torches must be changed by a qualied and skilled professional. Always use the correct size of
DIN connectors.
Always wear dry clothes in good condition to be insulated from the electrical circuit. Always wear insulated shoes in any
welding area.
MAGNETIC FIELDS AND INTERFERENCES
An electromagnetic eld is created around the cables by current ow.
According to the standard IEC 60974-10, this class A device is designed to be used in an industrial or professional envi-
ronment. It can be difcult to ensure electromagnetic compatibility, due to conducted disturbances as well as radiation.
17


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gys NEOPULSE 270-T2 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gys NEOPULSE 270-T2 in the language / languages: English, German, French as an attachment in your email.

The manual is 5,19 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info