625740
18
Zoom out
Zoom in
Previous page
1/48
Next page
18
GYSFLASH 50-24 HF
EN
1
Battery analysis
TRACTION CHARGE
2
Recovering damaged elements from an extended deep discharge
3
Sulphated battery test
4
Sulphated battery recovery
5
Checking the battery recovery
6
Battery charged to 80%
7
Battery charged to 90%
8
Battery cells refresh
9
Cells break time
10
Battery cells equalization
11
Battery charged to 100% (charge resumption after 48h)
PROTECTIONS
This device is protected against short-circuits and polarity inversions. It has an anti-spark feature which prevents sparks whilst
connecting this charger to the battery. This charger will not deliver current if there is no battery detected (no voltage in the clamps).
The charger is tted with an internal 80A fuse (ref. 054653), to protect against misuse.
TROUBLESHOOTING
TROUBLESHOOTING CAUSES REMEDIES
1
Screen ashing :
« #error (+)<-->(-) »
+ alarm beep
The polarity has been reversed on the clamps Connect the red clamp to the (+) and the black clamp to the (-) of the battery.
2
Screen ashing :
« #error U>Umax »
+ alarm beep
Battery voltage too high Charger not suitable.
3
Screen ashing :
« #battery error »
+ alarm beep
Battery in short-circuit or damaged Change the battery.
Battery not connected or clamps in short-circuit Check clamps connection.
Error on the battery voltage selection Charger not suitable.
4
Screen ashing :
« >50A »
+ alarm beep
Consumption exceeds the output of the charger Turn off electrical consumers to reduce power demand
5
The charger delivers a high current
(greater than 10A) before the dia-
gnostic tool has been activated.
Several consumers are active on the vehicle
The charger works to specication. Turn off consumers to check the battery is
not too discharged (see cause n°2).
Battery discharged
Battery deeply discharged, the charger delivers current to charge it. Wait until
the output current is below 10A to start the diagnostic.
6
Displays for 1s :
« no battery »
+ alarm beep
«Showroom mode is working on « no battery »
Showroom without battery : the charger operating normally.
To deactivate the «no battery» function, press the «START/STOP» key, and then
press the «START/STOP» key again to start the Showroom mode with battery.
7
The device is locked in Showroom
mode
Lock Showroom active
The charger works to specication.
See conguration menu to deactivate the function.
8
Screen displays :
« #error temp(°C) »
+ alarm beep
Faulty fan Contact your distributor.
Sun exposure
Do not leave the device exposed to sunlight.
Leave the device ON until the fault disappears. (The alarm beep can be stopped
Possibility to stop the alarm beep by pressing the START/STOP key).
9
Screen displays :
« #error IHM »
+ alarm beep
Electronic fault Contact your distributor.
10
Screen displays :
« #error fuse »
+ alarm beep
Mishandling
Internal fuse must be changed by a qualied person
(ref. 054653: 80A).
11
The device does not display
anything
Input fuse faulty
Input fuse must be changed by a qualied person
(temporised fuse 10A 5x20).
Faulty electrical network
Check the voltage of the electrical network is between 180V and 260V.
18


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gys GYSFLASH 50-24 HF at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gys GYSFLASH 50-24 HF in the language / languages: English, German, French, Spanish as an attachment in your email.

The manual is 2,56 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Gys GYSFLASH 50-24 HF

Gys GYSFLASH 50-24 HF User Manual - Dutch - 12 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info