625739
11
Zoom out
Zoom in
Previous page
1/52
Next page
11
GYSFLASH 50-12 HF
EN
CHARGE MODE CONFIGURATION DEPENDING
ON THE BATTERY TYPE
Charging curves available if activated in
«Advanced Menu».
Only for liquid, gel/AGM and expert
charging curves.
Start up :
• Connect the clamps : red to the (+) and black
to the (-) of the battery.
• Push the START/STOP key to start the charge.
• During the charge, the product alternates
between displaying the progressing percentage
of the charge, voltage, current, injected ampere
hours and elapsed time.
• Push the START/STOP key again to stop the
charge.
CHARGE MODE START UP
10%
12V
80Ah
CHARGE
CHARGE
Gel/AGM
U=12.5V
Q=2.5Ah
I=10A
00h22
NB: When the charge ends (100%), if the battery remains connected the charger maintains the charge level of the battery by
applying a oating voltage.
Precaution: Check the electrolyte level and ll if necessary before charging.
When charging on vehicle, it is recommended to reduce the electrical consumption of the vehicle to a minimum (switch off the lights,
close the doors...) in order to do not disturb the charging process.
DIAG+ MODE
On a stationary vehicle the GYSFLASH supplies up to 50A to test high-energy consumers: engine fan, window regulator, electronic
suspension, etc... By supplying a steady voltage:
- 12V to 14.8V
Voltage adjustment
It is possible to adjust the voltage in steps of 0.1V according to manufacturers specications.
DIAG + MODE CONFIGURATION
12.0V
12.1V
...
14.8V
DIAG+
U=13.5V
12V
DIAG+
U=13.2V
12V
Start up :
• Connect the clamps : red to the (+) and black to the
(-) of the battery.
• Push the START/STOP key to start the mode.
• During use the current consumed and the instanta-
neous voltage are displayed.
DIAG+ MODE START UP
I=12A
U=13.5V
DIAG+
U=13.5V
12V DIAG+ 12V
Precaution : Before using the Diag+ Mode. If the screen displays a current greater than 10A, it indicates the battery is discharged.
The device will start charging automatically. Check all electrical consumers are switched off on the vehicle. Wait until the current falls
below 10A and then re-launch the diagnostic.
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gys GYSFLASH 50-12 HF at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gys GYSFLASH 50-12 HF in the language / languages: English, German, Dutch, French, Spanish as an attachment in your email.

The manual is 2,44 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info