GYSFLASH 40-12 FV
EN
ADVANCED MENU
This menu controls the advanced parameters of the charger. To move from one parameter to another push the Select key :
SELECT
Activation «Change battery» > Activation «Power Supply» > Activation «Expert Curve» (> Adjusment of the
«Expert Curve» parameters)
• CHANGE BATTERY mode activation:
To activate the CHANGE BATTERY mode, select «ADVANCED MENU |
Change bat: ON». Now this mode will be accessible from the mode list.
• POWER SUPPLY mode activation:
To activate the POWER SUPPLY mode, select «ADVANCED MENU | Power
Supply: ON». Now this mode will be accessible from the mode list.
• «EXPERT» curve activation:
To activate the «RECOV» curve, select «ADVANCED MENU | Expert curve:
ON». Now this curve will be available in the charging curves list from the
CHARGE mode.
• Parameters adjustment of the «Expert» curve:
If the charging curve is activated, the charging curve parameters can be
adjusted (type IU
0
I
0
U):
- Ucharge: Charge voltage adjustable from 12.0 to 16.0V (Step 7).
- Urecovery: Recovery voltage adjustable up to 30.0V.
If the value «OFF» is selected the recovery function is inactive (Step 2
and 4).
- Uoating: Floating voltage adjustment.
If the value «OFF» is selected the oating function is inactive (Step 9).
- Trecovery: Maximum time for shorted cells recovery, adjustable from
1h to 12h (Step 2).
- Trefresh: Time for the refreshing phase adjustable from 1h to 12h. If
the value «OFF» is selected, the refresh function is not activated (Step 8).
- T desulfat: Maximum time adjustable from 1h to 12h of the desulfation
phase (Step 4).
- T ch_max: Maximum charging time (Step 7 and 8).
- T ch_min: Minimum charging time (Step 7 and 8).
- Urefresh: Maximum voltage during the cooling phase (Step 8).
- OCP (Over Charge Protection): Maximum percentage of the nominal
capacity which can be injected before the protection begins.
aWarning:
When charging in-situ, a «Urecovery» or «Urefresh» too high
might damage the electronics of the vehicle. We advise NOT to
adjust these settings above 15V.
To save and validate the new settings, select «ADVANCED MENU» | save? Yes»
Push the «MODE» key to exit the «Conguration» menu.
ADVANCED MENU
ON
OFF
ADVANCED MENU
Power Supply: OFF
EXPERT CURVE
Uoating: OFF
EXPERT CURVE
Ucharge: 14.3V
EXPERT CURVE
Urecovery: OFF
ON
OFF
ON
OFF
ADVANCED MENU
expert curve: OFF
EXPERT CURVE
T recovery*: 5h
1h
2h
...
12h
EXPERT CURVE
T desulfat: 12h
1h
2h
...
12h
EXPERT CURVE
Tch_max: 16h
1h
2h
...
36h
EXPERT CURVE
Tch_min: 0h
0h
1h
...
Tch_max
EXPERT CURVE
T refresh: 5h
OFF
1h
2h
...
12h
EXPERT CURVE
U refresh: 17.0V
Uch
...
30.9V
31.0V
EXPERT CURVE
OCP: 200%
100%
...
245%
250%
ADVANCED MENU
Save? No
Yes
No
RETURN
OFF
Uch
...
29.9V
30.0V
12.0V
12.1V
...
16.0V
OFF
12.0V
12.1V
...
Uch
ON
OFF
ADVANCED MENU
Change bat.: OFF
15


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gys GYSFLASH 40-12 FV at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gys GYSFLASH 40-12 FV in the language / languages: English, German, Dutch, French, Spanish as an attachment in your email.

The manual is 2,47 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info