Recommendation to reduce electro-magnetic emission
a. Mains power supply: the equipment must be connected to the power mains as specified in the Manufacturer’s instructions. If interference
occurs, additional precautions such as filtering of the mains supply may be required. The supply cable in the welding machine’s permanent
installations may have to be screened in metal conduits or similar. The screening should be electrically continuous for the entire length of the
cable. It should also be connected to the welding machine with a good electrical contact between the metal conduit and the casing.
b. Welding cables: The welding cables should be kept as short as possible and should be positioned close together, running at or close to the
floor level.
c. Protection and reinforcement: Selective screening and shielding of other cables and equipment in the surrounding area may alleviate
problems of interference. Screening of the entire welding area may be considered for special applications
d. Connect the earth directly to the metal piece to be welded: Where necessary, the connection of the workpiece to earth should be
made by a direct connection to the workpiece, but in some countries where direct connection is not permitted, the connection should be
achieved by suitable capacitance, selected according to national regulations.
T
ROUBLESHOOTING
Anomalies Causes Remedies
Thermal protection light switched on, the
welding unit do not supply current.
The thermal protection of the welding unit is
switched on.
Wait until the end of the cooling phase.
Only the green indicator is on but you cannot
weld.
Connection failure of the earth clamp or
electrode holder.
Check the connections.
If, when the unit is on and you put your hand
on the welding unit’s body, you feel tingling
connection.
The welding unit is not correctly connected to
the earth.
Check the plug and the earth of your electrical
network.
Your unit does not weld correctly. Polarity error (+/-).
Check the polarity advised on the electrode
packaging.
The green indicator is on but the fan does not
work or not continuously, no power when
welding.
Power supply other than 230 or 400V
(EXPERT 220 DV)
Check if the plug delivers the correct voltage.
Switch off the machine for 2-3 minutes and try
again.
D
ECLARATION OF COMPLIANCE
The equipment described on this manual is complies with the instructions of low voltage 2006/95/CE of 12/12/2006, and the instructions of CEM
2004/108/CE of the 15/12/2004. This conformity respects the standards EN60974-1 of 2005, EN 50445 de 2008, EN60974-10 of 2007.
CE marking was added in 2012.
01/06/12
Société GYS
134 BD des Loges
53941 Saint Berthevin
Nicolas BOUYGUES
Président Directeur Général
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gys Expert 130 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gys Expert 130 in the language / languages: English, German, French as an attachment in your email.

The manual is 2,25 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info