665732
21
Zoom out
Zoom in
Previous page
1/82
Next page
21
EXAGON 400 CC/CV
EN
SAVE AND LOAD WELDING SETTINGS
The current settings are automatically saved and loaded at start up.
On top of the current settings, it is also possible to save and load 50 settings per each mode.
The memory recalls :
- Primary setting
- Secondary setting (MMA, CV)
- Secondary settings (MMA)
Save new settings :
- Maintain buttons and during 3 seconds. appears, release the buttons.
- Turn one of the two knobs . Validate by pressing the button .
- The display indicates a memory set (01 to 50) while blinking.
- Turn the knob to select the memory set in which the desired settings will be saved. Validate by pressing the button
.
- The settings are saved / the menu exit is instantaneous.
Load existing settings :
- Maintain the buttons and during 3 seconds. appears, release the buttons.
- Turn one of the two knobs to display . Validate by pressing the button .
- The display indicates a memory set (01 to 50) while blinking.
- Turn one of the two knobs to select the memory set containing the desired settings to load. Validate by pressing the button .
The settings are loaded / the menu exit is instantaneous.
REMOTE CONTROL
CONNECTIONS AND RECOMMENDATIONS
The remote control works in all modes (except in semi-auto mode with a workshop wire feeder where all controls are on the wire feeder).
The remote control acts on the primary settings of the current process (MMA and TIG, voltage and gouging).
Connections :
1- Plug the remote control on the machine’s front.
2- The machine will detect the remote control automatically and open a selection menu:
Foot pedal selection.
Remote control with potentiometer selection.
The remote ontrol type selection is done with the two knobs, the validation is done with the button
.
The LED (FIG-2, n°14) switches on.
It is possible to activate / deactivate the remote control without having to physically unplug the remote control. Press the button , for 3
seconds, the LED (FIG-2, n°14) indicates the state of the remote control (LED on = remote control on).
Operations :
• Manual remote control (GYS product ref. 045675).
The manual remote control can adjust :
- the current from 50% to 100% of the set intensity using the main knob. The displayed current setpoint matches the potentiometer position. The
displayed current setpoint becomes a 100% of the settings when the main knob is turned towards the machine’s keypad.
- from minimum to the maximum of the voltage range (then the main knob has no effect). The voltage display shows the remote control variation.
Foot pedal (option ref. 045682) :
The pedal control can adjust :
- the current from 50% to 100% of the set intensity using the main knob. The displayed current setpoint corresponds to a 100% of the value.
Connectors
Beyond the manual remote control and the pedal, it is possible to create you own connectors using the optional male socket (ref. 045699). For the
cabling layout, please see the diagram below utiliser a 10 kΩ potentiometer).
F
A
F
CD
E
G
D
C
B
A
ref. 045699 External view Electric diagram according to the remote control type.
21


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gys EXAGON 400 CC-CV at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gys EXAGON 400 CC-CV in the language / languages: English, German, Dutch, French, Italian, Spanish as an attachment in your email.

The manual is 4,68 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info