EASYMIG 130 / 140 / 150
EN
14
ELECTRIC SAFETY
The machine must be connected to an earthed electrical supply. Use the recommended fuse
size.
An electrical discharge can directly or indirectly cause serious or deadly accidents.
Do not touch any live part of the machine (inside or outside) when it is plugged in (Torches, earth cable, cables,
electrodes) because they are connected to the welding circuit.
Before opening the device, it is imperative to disconnect it from the mains and wait 2 minutes, so that all the
capacitors are discharged.
Do not touch the torch or electrode holder and earth clamp at the same time.
Damaged cables and torches must be changed by a qualied and skilled professional. Make sure that the
cable cross section is adequate with the usage (extensions and welding cables). Always wear dry clothes in
good condition, in order to be insulated from the electrical circuit. Wear insulating shoes, regardless of the
environment in which you work in.
CEM CLASSIFIED MATERIAL
These Class A devices are not intended to be used on a residential site where the electric
current is supplied by the public network, with a low voltage power supply. There may be
potential difculties in ensuring electromagnetic compatibility on these sites, because of the
interferences, as well as radio frequencies.
This equipment does not comply with IEC 61000-3-12 and is intended to be connected to
private low-voltage systems interfacing with the public supply only at the medium- or high-
voltage level. On a public low-voltage power grid, it is the responsibility of the installer or
user of the device to ensure, by checking with the operator of the distribution network, which
device can be connected.
ELECTROMAGNETIC INTERFERENCES
The electric currents owing through a conductor cause electrical and magnetic elds
(EMF). The welding current generates an EMF eld around the welding circuit and the
welding equipment.
The EMF elds may disrupt some medical implants, such as pacemakers. Protection measures should be taken for
people wearing medical implants. For example, access restrictions for passers-by or an individual risk evaluation
for the welders.
All welders should take the following precautions in order to minimise exposure to the electromagnetic elds
(EMF) generated by the welding circuit::
• position the welding cables together – if possible, attach them;
• keep your head and torso as far as possible from the welding circuit;
• never enroll the cables around your body;
never position your body between the welding cables. Hold both welding cables on the same side of your body;
• connect the earth clamp as close as possible to the area being welded;
• do not work too close to, do not lean and do not sit on the welding machine
• do not weld when you’re carrying the welding machine or its wire feeder.
14


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gys EASYMIG 150 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gys EASYMIG 150 in the language / languages: English, German, Dutch, French, Italian, Spanish as an attachment in your email.

The manual is 4,11 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info