DIAG-STARTIUM 60-12 / 60-24
EN
WARNING
WARNING! Explosive gas , avoid ames and sparks . During charging, the battery should be placed in a ventilated
area.
• Protect the unit from rain and moisture
If the power cable is damaged it must be replaced by the manufacturer , its after sales department or a similarly
qualied person to avoid hazard.
• The external fuse can be replaced and the circuit breaker can be engaged by the user.
• Under no circumstances should this appliance should be used to charge accumulators or non rechargeable batteries.
• Respect the connection sequence indicated .
• Product subject to separate collection , do not dispose in domestic waste .
This appliance is not intended for use by persons (including children) with reduced physical , sensory or mental
capabilities, or lack of experience or knowledge, unless they are supported by a person responsible for their safety,
supervision or instruction concerning use of the appliance .
• Do not open the device. Modications not performed by the manufacturer's technician will void the warranty .
• Check that the available input voltage corresponds to the one indicated on the nameplate of the charger.
TROUBLESHOOTING
Troubleshooting Causes Remedies
Error LED ashes Power supply issue. Check the power supply.
Error LED ashes and alarm beep Clamps in short-circuit or polarity
reversal.
Check if the fuses have blown.
Do not put the clamps in short-circuit.
Reverse the polarity.
The battery is faulty. Check the voltage at the battery
terminals with a voltmeter. If the
voltage instantaneously increase
by more than 2.5V by element the
battery can be sulphated or damaged.
Voltage error (6V-12V-24V) Check if the battery is correctly
connected either in 6V, 12V or 24V.
Battery not detected or <1V. Display :
«BAt HS»
Connect the battery.
Select TIMER if the battery voltage is
<1V.
After intensive use the device goes to
thermal protection. Display : «th»
Wait 1/4h for the device to cool
down.
The LEDs won't light up Power supply issue. Check the power supply.
The internal fuse is melt. Send the device back to GYS after
sales.
The ON/OFF switch is not engaged. Switch the ON/OFF button.
In START ENGINE mode, if the screen
displays 0%. Restart impossible.
The battery is sulphated, start
is avoided to protect the vehicle
electronics.
Recharge the battery prior using
START ENGINE.
Battery is boiling. The voltage selected 12 or 24V is not
correct.
Check the battery voltage and
connect it following the recommended
connection.
The battery has element in short-
circuit.
The battery cannot be recovered, it
must be replaced.
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gys DIAG-STARTIUM 60-12 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gys DIAG-STARTIUM 60-12 in the language / languages: English, German, Dutch, French, Spanish as an attachment in your email.

The manual is 1,45 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info