15 Troubleshooting
FAULT
POSSIBLE CAUSES
MEASURES
Mobile air
conditioner does
not start.
Mains plug is not plugged
into the plug socket.
Check whether the mains plug
has been plugged in correctly.
Display “Full” is lit.
Empty the water tank.
Room temperature is lower
than the set temperature.
Lower the set temperature.
The mobile air
conditioner is
not operating
with the
expected
effectiveness.
Insufficient
cooling.
Doors and/or windows are
not properly closed.
Close all doors and windows,
etc. through which warm air
may enter.
There are additional heat
sources in the room.
Remove heat sources, if
possible.
Temperature is set too
high.
Lower the set temperature.
Air inlet or outlet is
blocked.
Remove objects from the air
inlet/outlet. Clean the air filter
and air outlet. Maintain the
specified minimum clearances.
Air is not blown
out.
Air filter or air outlet is
blocked.
See above.
Operating
noises.
The appliance is not
standing on a level and
stable surface.
Place the appliance on a level
and stable surface.
Air filter or air outlet
blocked.
See above.
Appliance makes “flowing”
noises.
Flowing noise of the refrigerant.
No measures necessary.
Water runs out.
Water drain hose has come
loose or is damaged.
Inspect the water drain hose for
damage and check for correct
installation; replace or install
correctly, as necessary.
Water drain hose is
blocked.
Remove any obstacles and
straighten the water drain hose.
Drain hole not properly
closed. Drainage plug is
damaged.
Check whether:
- The drain hole is properly
closed.
- The plug is damaged.
34


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gutfels CM 80949 WE at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gutfels CM 80949 WE in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 1,42 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info