Page | 31
13.1 Setting the SLEEP
function
1. With the appliance in COOL
mode, start the SLEEP
function with button “b”
(SLEEP).
2. The fan runs at the lowest
speed and the temperature is
controlled for max. 8 hours.
3. 0 2 hours: Increase by 1°C
per hour.
4. 2 - 4 hours: Temperature is
kept constant.
5. 6 - 8 hours: Decrease the
temperature by 1°C per hour.
NOTE
The function is only available in
cooling mode.
Using the SWING function
Setting of the air flow for a more
comfortable and better air
circulation.
1. Activate the SWING function with
button “a”.
2. The air flow direction (louvres)
moves from left to right.
3. Fix the air flow direction
(louvres) in the respective
position by pressing button “a”
again.
13.2 MODE description
Select the operating mode between
FAN, DEHUM, COOL and AUTO with
button “d” (MODE).
When changing from COOL to
DEHUM mode (and vice versa),
allow an ON/OFF interval of 3
minutes.
FAN ventilation mode
Set the fan speed with button
“h” (SPEED).
DEHUM
The appliance automatically
lowers the current room
temperature (between 16°C and
31°C) by 2°C.
The fan speed is automatically
set to “low” (LOW).
COOL cooling mode
Set the temperature 16°C and
31°C with buttons “e/g”
(DOWN/UP).
Set the fan speed with button
“h” (SPEED).
Setting the fan speeds
Set the fan speed to low (LOW),
medium (MEDIUM) or high (HIGH)
with button “h” (SPEED).
Water tank alarm function
The water tray inside the mobile air
conditioner has a water level safety
switch which monitors the water
level. When the water level reaches
an expected height, the indicator
light “j” (FULL) comes on.
13.3 Connecting water drain
hose
Note that the water drain hose
connected to the mobile air
conditioner must not run higher than
the position of the hose connection
on the mobile air conditioner at any
point, as otherwise condensation
may flow back into the mobile air
conditioner and damage the
appliance.
Disconnect the mobile air
conditioner from the mains power
supply before installing the water
drain hose.
31


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gutfels CM 80949 WE at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gutfels CM 80949 WE in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 1,42 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info