Inspection and maintenance plan
Time interval Description Any other details
As needed Cleaning and rinsing out
After 12 months Oil change
5
10 W - 40, max 100 ml
Failures – causes - removal
Failures Causes Removal
Engine does not start No power supply.
Blocked pump wheel
Floating switch in shutdown position
Check the voltage
Visually inspect the pump wheel for foreign
objects
Check the water level
Pump does not suck Water level too low
Blocked pump wheel
S
Remove the obstruction
water pumped
The crusher wheel is dirty
Water level quickly drops down
Maximum head of delivery exceeded
Broken piping
Clean the crusher wheel
Check the transport line
Check the transport line
EC-Declaration of Conformity
GÜDE GmbH & Co. KG
Birkichstrasse 6, 74549 Wolpertshausen
Deutschland
We, hereby declare the conception and construction
of the below mentioned appliances correspond - at
the type of construction being launched - to appro-
priate basic safety and hygienic requirements of EC
Directives. In case of any change to the appliance not
Plunge pump
PRO 1100 A #75800
PRO 2200 A #75805
PRO 2201 S #75810
Appropriate EU Directives
2006/95 EG, 2004/108 EG
Harmonised standards used
EN 55014-1:2006 + A1:2009
EN 55014-2:1997 + A1:2001 + A2:2008
EN 61000-3-2:2006 + A1:2009 + A2:2009
EN 61000-3-3:2008
EN 50366:2003 + A1:2006
EN 60335-1:2002 + A11:2004 + A1:2004 + A12:2006 +
A2:2006 + A13:2008 + A14:2010
EN 60335-2-41:2003 + A1:2004 + A2:2010
Wolpertshausen, 2012-01-13 Helmut Arnold
Managing Director
Technical documentation Joachim Bürkle
Güde Schmutzwasser-Tauchpumpen_final.idml 14 13.01.12 16:44
18


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gude Pro Pro 2200 a 75805 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gude Pro Pro 2200 a 75805 in the language / languages: English, German, Dutch, French, Italian as an attachment in your email.

The manual is 4,58 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info