Supply includes
Picture 1:
1. Case
2. Oil bottle
3. Handle
4. Compressed air connector
5. 5 individual cutters
Appliance
8-piece PRO set of pneumatic demolition hammer
Professional pneumatic demolition hammer with a flap lock for quick
cutter exchange with 5 individual cutters. The demolition
hammer can without any problem be used for banging of facings and
exterior plaster, knocking off screws, punching of metal plates,
creating grooves in walls and breaking through walls.
Rubber handle and foul air channel.
GB
EU Declaration of Conformity
We, Güde GmbH & Co. KG Birkichstraße 6, 74549 Wolpertshausen,
Germany, hereby declare the conception and construction of the be-
low-mentioned appliances correspond - at the type of construction
being launched - to appropriate basic safety and hygienic require-
ments of EC Directives.
In case of any change to the appliance not discussed with
us the Declaration expires.
Marking of appliances:
8-piece PRO set of pneumatic demoli-
tion hammer
Order No. 75180
Date/producer signature: Oct 28, 08
Signed by: Mr Arnold, Managing Director
Appropriate EU Directives:
2006/42/EG
Harmonised standards used:
EN 792-4+A1:2008
Technical data
Service pressure: 6.3 bar
Air consumption: 240 l/min
Air connector-thread: ¼”
6-square cutter fixture 10 mm
Strokes per minute: 3,000
Stroke length: 67 mm
Weight: 1.7 kg
Recomm. hose cross section: 10 mm
L
WA
noise level: 103 dB
Vibration acceleration: 13.8 m/s²
General safety instructions
The Operating Instructions need to be completely
read before first use of the appliance. Should any
doubts concerning the appliance connection and han-
dling arise, please contact the producer (service de-
partment).
Handling
Never aim with the tool end that strikes at yourself or
any other person. The appliance is connected with the
compressed air supply hose. Use the pneumatic ap-
pliance with allowed service pressure only.
Safety provisions
Protect yourself and your surroundings against acci-
dents using suitable safety measures.
Do not touch striking parts.
Do not use the demolition hammer to any other
purposes than to which it has been designed.
Secure the pneumatic tools before children.
Work only when not tired and able to concen-
trate.
Compressed air connector via quick-acting
coupling only.
Working pressure needs to be adjusted by a
reducer.
Do not use oxygen or inflammable gases as a
source of energy.
Disconnect the appliance from the compressed
air source before removing any failure.
Use original spare parts only.
Never let the appliance run with no load at full
free-running revolutions.
Wear necessary protective clothes, especially
ear protectors when working with the demolition
hammer.
Use the appliance with service pressure only.
Do not needlessly use long pneumatic hoses to
avoid tripping.
Sparks can be generated when cutting. Beware
of combustible materials in the surrounding ar-
ea.
Maintenance and treatment
Trained persons are allowed to execute the
maintenance works only.
Following the mentioned instructions for mainte-
nance is a guarantee for a long service life and
trouble-free operation of this high-quality product.
Disconnect the appliance from the compressed air
source at maintenance and treatment. For perma-
nent faultless operation of your appliance it is nec-
essary to ensure everyday cleaning and regular lu-
bricating. Use special pneumatic oil only.
You can choose from the following options:
a) Via mist lubricator
The complete maintenance unit contains a mist
lubricator and is attached to the compressor.
b) Via lubricator on the piping
In the immediate vicinity of the appliance (in a
distance of app. 50 cm) a lubricator is installed
on the piping that supplies sufficient volume of
oil to the appliance.
c) Manually
If your equipment has no maintenance unit or
lubricator on the piping you need to add 3 – 5 oil
drops to the compressed air connector before
each putting the pneumatic appliance into op-
eration. If the pneumatic appliance is not used
for several days you must add 5 – 10 oil drops to
the compressed air connector before starting the
appliance. Store the pneumatic tools/appliance
in dry rooms only.
The air hose must be removed and more pneumatic
oil poured in the air intake every three months or
when the demolition hammer is used less often. Re-
connect the air hose and let the demolition hammer
run for app. 30 seconds so that the compressor en-
gine was cleaned. After cleaning, follow the lubrica-
tion instructions.
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gude Pro 8 TLG PRO 75180 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gude Pro 8 TLG PRO 75180 in the language / languages: English, German, Dutch, French, Italian as an attachment in your email.

The manual is 1,68 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info