Unit Scope of Supply (Fig. .1)
1. Control lever
2. Pneumatic coupling
3. button (turning direction change)
1200 PRO pneumatic angle grinding machine
Professional pneumatic angle grinding machine for works in
places difficult to approach, with a 3/8 quick chuck. Due to the
foul air channel, there is no dust swirl on the work-piece.
EU DECLARATION OF CONFORMITY
We,
Güde GmbH & Co. KG
Birkichstrasse 6
D-74549 Wolpertshausen
Germany
herewith declare that the following appliance complies with the
appropriate basic safety and health requirements of the EU
Directives based on its design and type, as brought into circulation
by us
.
In case of alternation of the machine, not agreed upon by
us, this declaration will lose its validity.
Machine description:
1200 PRO pneumatic angle grinding machine
Article No.
#75155
Applicable EU Directives:
2006/42 EG
Applicable harmonised standards:
EN ISO 12100-1:2003
EN ISO 12100-2:2003
EN ISO 14121-1:2007
EN 792-3+A1:2008
EN 15744:2008
EN 28662-1:1993
Date/authorised signature: 24.11.2010
Title of signatory: Managing Director
Mr Arnold
Technical documentation:J. Bürkle FBL; QS
Guarantee
Guarantee claims according to the guarantee certificate
attached. Please, understand that we are unable to accept the
guarantee for the following reasons:
• Breach of operation and service instructions.
Necessary cleaning neglect.
• Forcible use, unprofessional handing, misuse or accident.
• Laic interventions or unprofessional attempts to do a repair.
Technical data
Operating pressure 6,3 bar
Air consumption 150-450 l/min
Air connection screw 1/4"
Tool hold 1-10 mm
Max. free-running revs 1200 U/ min
Recomm. hose cross sect. 10 mm
Noise data LWA 95 dB
Weight 1,1 kg
Operation
Do not direct the rotating end of the tool against yourself or
against other persons. Connect the tool with the air supply hose
If seal has not yet been applied on the pneumatic insertion
wrap it with a Teflon tape (picture 2 and 3)
General safety instructions
Safety notice! Failing to follow these
instructions can cause an injury to you or other
persons.
Protect yourself and your surroundings against accidents using
suitable safety measures.
1. Read the following Operating Instructions for using the
pneumatic appliance and follow the safety instructions for
using the pneumatic appliance.
2. Properly maintain the appliance and follow all instructions
for appliance lubrication and maintenance.
3. Never exceed the prescribed service pressure
4. Do not use the angle drilling machine to any other purpose
than prescribed
5. Protect the pneumatic tools from children.
6. Get down to work well-rested and concentrated.
7. Pneumatic connection via a fast-acting clutch only.
8. Set-up the work pressure on reduction valve.
9. Do not use oxygen or inflammable gases as the source of
energy.
10. Before removing failures, disconnect the unit from the
source of pressure air.
11. Use only the genuine spare parts.
12. Never let the unit idle at full.
13. Always wear eye and ear protection
14. Always wear safety gloves.
15. Do not use any unnecessarily long delivery hose to
prevent a risk of trip.
16. ATTENTION: Do not exceed the maximum pressure of
6.3 bar.
17. Never leave the pneumatic appliance unattended.
18. Never put the appliance near people or animals.
19. Never aim at people or animals with the air current.
20. Never put the pneumatic appliance near body holes – it
can lead to injuries dangerous to life!
Attention! You can get caught by the rotary tool!
Maintenance and Care
Only trained persons ate allowed to do the maintenance.
Observing warning commands shown in the Lasting and
trouble-free function of your ratchet screwdriver is grounded on
regular lubrication. Use only a special tool oil. Pick up a
possibility of lubrication: Use only a special tool oil. Pick up a
possibility of lubrication.
Ways of lubrication are following:
a) Via a beam added lubricator
The full maintenance unit include a beam added
lubricator and is placed on the compressor.
b) Via a lubricator on the piping
A lubricator installed on piping supplying the unit with
sufficient amount of oil in an immediate distance from
the unit (approximately 50 cm).
c) Manually
If there is no maintenance unit or a lubricator on piping, 5-6
drops of oil should be put in pneumatic connection before
every putting in operation.
Store the pneumatic tool in dry rooms.
You need to disconnect the air hose and pour in large volume of
pneumatic oil to the air intake every three months or when the
angle grinding machine is used only occasionally. Reconnect the
air hose and let the angle grinding machine run for app. 30
seconds to enable compressor engine cleaning. Follow the
lubricating instructions after cleaning.
7
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gude Pro 1200 PRO 75155 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gude Pro 1200 PRO 75155 in the language / languages: English, German, Dutch, French, Italian as an attachment in your email.

The manual is 2,18 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info