Every effort is made to improve our products continuously. Therefore, technical data and figures are subject to change
Unit
Scope of Delivery
# 94667 – HWW 3100 K
Fig. 8
Ideal to supply households, gardens, farms and agricultural
areas with water
1. Pump connection
2. Filler cap and bleed screw
3. Suction connection
4. Pressure hose
5. Pressure switch
6. Air receiver feet
7. Air receiver
8. Pump body
9. Drain screw
10. Air valve
11. pressure gauge
12. Air valve
13. Manometers
Guarantee
A warranty period of 12 months applies to commercial use and 24 months apply to private use and commences on the day of
purchase of the device.
Warranty applies exclusively to failures due to defective material or workmanship. An original sale slip with indication of date of sale
must be presented in case of claiming for the warranty rights.
Warranty does not cover unprofessional use such as device overload, violent use, damage caused by third party or foreign materials,
failure to comply with operations and assembly manual, and normal wear and tear.
General Safety Instructions
Prior to the initial use of the unit, the operating instructions should be read completely. If in doubt with regard to connection and
operation of the unit, consult the manufacturer (servicing department).
Follow the instructions below carefully in order to secure a high degree of safety:
Caution: Always operate with FI (stray current protection switch)!
The pump should never be operated as a swimming pool circulating pump.
The pump should not be used in swimming pools. Only professional is allowed to do the electric installation. The pump should be
fed vi a stray current protection switch dimensioned at 30 mA max.
Do not let the pump dry-run without any water supplied. It would threaten the service life of the pump and damage the motor.
Never wrap the pump head in a blanket or a cloth in an attempt to prevent the water getting frozen in a cold weather.
Never use the pump at the outdoor temperature above 40°C or below 0°C and with water at the temperature above 35 °C.
Take care no to use the pump with r fluids other than water
Avoid water with sand, it may damage the sealing.
Read instruction for operation carefully before assembly and putting in operations and follow the instructions with care. Persons
not familiar with the pump operation are recommended to read the operation and maintenance manual thoroughly prior to putting the
unit in operation so that the risk of damaging it is avoided.
The user is to be held liable to third persons while at the workplace
The pump should not be put in operation unless equipped with a cable or a rubber-coated extension cable type H07RNF, subject
to standards DIN 57282 or DIN 57245.
The pump should not be lifted, fixed or moved by connecting electric cable
You should make sure that the plug connections are protected from the moisture and possible floods.
Check to see that the connecting cable and the plug are in good order before the use. Place the pump ob a flat, stable, horizontal
base.
Unplug the pump before doing any work on it.
The user shall be held liable for observing the local safety and assembly regulations.
If the pump is defective, only an authorised workshop should do the repair. Only genuine spare parts should be used.
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gude HWW 3100 K at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gude HWW 3100 K in the language / languages: English, German, French, Italian as an attachment in your email.

The manual is 4,88 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info