Remaining Dangers and Protection Measures
Electric Remaining Dangers
Danger
Description
Protection Measures
Direct
electric
contact
Electric shock
Insufficient current switch FI
Indirect
electric
contact
Electric shock
via the medium
Insufficient current switch FI
Disposal
Disposal instructions are illustrated in the form of pictograms
on the device or packaging. Description of the pictograms is
given in "Identification" chapter.
Disposal of transport packaging
Packaging protects the device against damage during
transport. Packaging materials are usually selected according
to their effect on environment and disposal methods and can
therefore be recycled.
Returning of the packaging back to circulation saves
resources and costs for packaging disposal.
Parts of the packaging (e.g. foil, styropor) may be dangerous
for children. Risk of suffocation!
Keep these parts of the packaging out of reach of children
and dispose as soon as possible.
The Requirements on the Operator
The Operator shall carefully read the Operation Manual
before using the device.
Qualification
The professionaly versed person does not need any special
qualification for using the device.
Minimum Age
The devfice may only be operated by persons at the age of 16
and more. The exception is using the device by an adolescent
in the course of his training for the profession, where the
device is used for the purpose of getting the skill under
supervision of the instructor.
Training
The operator who is going to operate the device will only need
to get corresponding training by a professionally trained
person, and/or a training according to the Operation Manual.
No special training is necessary.
Technical data
HWW 1300 G
Supply main
230 V / 50 Hz
Engine P1 output
1300 W
Max. suction height
7,5 m
Max. pumped quantity
4000 l/min
Max. pumping height
48 m
Pressure supply main
1“
Suction supply main
1’’
Way of protection
IP X4
Water temperature
35 °C
Vessel
24 l
Weight approx.
19,6 kg
Assortment position No.
94195
Transport and Storing
When storing in winter, make sure that no water is in
the device, otherwise the device may be destroyed due to
freezing.
Assembly and First Putting into Operation
Filter and Screen for Impurities
If the water contains sand, the pump shall be operated with
the filter for impurities (available as accessory) located on the
suction supply main of the pump. Should the sand penetrate
into the friction circle sealing (connecting shift pump) the
sealing would be destroyed. If this occurs in the course of
guarantee term, it will be qualified as a fault caused by the
user and this case will be excluded from any provision of
guarantee.
Safety Instructions for First Putting into Operation
Caution: The pump shall never be operated without
water.
When using the pump (water equipment) the user is
responsible to third persons
The user may operate the pump only on connecting lines
furnished with the insufficient current switch (FI switch)!
Before putting into operation the authorized electrician should
check if there are required electric safety measures available.
The electric connection shall be performed by means of a
socket.
Voltage examination. Technical data on the label shall comply
with the electric network voltage.
If the pump is used for ponds, wells etc. and in corresponding
water equipments, the standards applicable in the countries where
the pump is used shall be unconditionally observed.
Electric pumps used outside (e.g. at the ponds etc.) shall be
furnished with rubber electric cable type H07RNF, according to
standard DIN 57282 or. DIN 57245.
When the pump is in operation, no people or animals are
allowed to stay in the liquid being repumped (e.g. in
swimming pools, in cellars etc.).
The repumped liquid temperature shall not exceed +35 °C.
Should extension cables be used, they shall be made
exclusively of rubber, type H07RNF, according to standard
DIN 57282 or DIN 57245. The pump connected to the
electric network shall never be touched by a cable, never
lifted by holding the cable or transport by means of a cable.
The connecting socket shall always be in necessary
distance from water and moisture and the plug shall be
protected against moisture.
Before putting the pump into operation check if the electric
cable and/or the socket are not damaged.
Before performance of any works on the pump the plug
shall be pulled out of the socket..
If the pump is built-in in a gully, the gully shall be covered
with cover to ensure the safety of people walking there.
The pump shall never be installed in moist shifts
(danger of shortcut, damage caused by corrosion)!
For avoiding or prevention of possible damage (as e.g.
flooding the rooms etc.) due to faulty pump operation
(e.g. due failure or defects) the owner (user) shall take
reasonable safety measures (installation of alarm
equipment, a spare pump etc.)
In case of failure on the pump,. the repair shall be
performed exclusively by an authorized service
repairshop.Only original spare parts may be used.
We have to draw your attention to the fact that
according to the valid standards we cannot take
11
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gude HWW 1300 G 94195 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gude HWW 1300 G 94195 in the language / languages: English, German, Dutch, French, Italian as an attachment in your email.

The manual is 2,33 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info