Before putting the pump into operation, check w hether the
electric cable and/or the socket are not damaged.
Unplug the appliance before any w ork on the pump.
The pump must never be installed in moist shafts (risk
of shortcut, damage as a result of corrosion)!
To avoid or prevent a possible damage (e.g. flooding a
room, etc.) due to defective pump operation (e.g. failure
or defects), the owner (user) is obliged to take
reasonable safety m easures (installation of alarm
equipment, a spare pump etc.).
If the pump is defective, repair must exclusively be executed
by an authorised service centre. Original spare parts to be
used only.
Let us refer to the fact that we will not assume any
liability under the standards in force for any damage
caused by our appliances in the cases mentioned below.
Unauthorised repairs executed by unauthorised service
centres.
Using the appliance in conflict w ith the designation or failure
to use the appliance as designated.
Pump overloading by continuous operation.
Thermal fuse
A probe is built into the engine that automatically sw itches the
pump off if a certain temperature has been exceeded and/or
sw itches the pump on after it has been cooled. This increases
the service life of the pump for several times and prevents
thermal damage of the electric engine.
Thermal fuse/engine circuit switch
Cooling dow n time is app. 25 minutes; after the pump is
automatically sw itched on, prevent any dangerous situation
related to automatic starting. If the engine circuit sw itch is
sw itched on, it is necessary to detect the cause and remove
it (see “Troubleshooting“). Information given here cannot be
used forhome-executed” repairs as they require specific
expert know ledge. A customer service centre must alw ays
be contacted w hen any failures are faced.
To prevent pump overheating, appropriate air supply
must be provided!
Not to be put to tight or moist shafts and not to be
covered!
Safety instructions for the operator
The appliance to be used only after the Operating Instructions
have carefully been read.
Safety instructions included in these Operating Instructions
must be follow ed.
Behave responsibly to other persons.
Operation
Unplug the appliance.
Filter installation (filter not included in the supply!)
Assembly (see pic. E)
Watch the flow direction
Tighten the screw (see pic. B)
Bleed the appliance after being filled (pic. C/E)
Max. pressure of 5 bar
Protect against frost
Clean the filter regularly w ith a brush and clean w ater
Air pressure
Open the consumer valve, e.g. w ater cock, so that the w ater
in the system can be put through.
Screw dow n the protective air valve cover (F)
Using a compressor and tyre filler, check the air pressure in
the tank.
Specified air pressure of 1.5 ± 0.3 bar.
Bleeding
Release the bleeder screw to release any contained air (pic.
A; pos. 10)
Drainage
To drain the pump, release the drain screw (pic. A; pos. 11).
Pressure in the tank
The manufacture-set cut-off pressure is 3 -4 bar after filling is
completed.
The preliminary pressure in the tank (air) is 1.5 ± 0.3 bar and
it must be regularly checked and adjusted (G).
Step-by-step instructions
Connect the suction pipeline
with a reverse
valve (foot valve) corresponding to the suction
pipeline connection to (C).
Tighten all screw connections of the pump by a seal
band (B) AT ALL TIMES.
Before filling, remove the bleeder screw (pic. A; pos.
10) on the back side of the pump and on the
pressure piping connection (pic. A; pos. 2 and 1). Fill
the appliance in a way water runs out of the bleeder
hole. (C) Bleed the filter as well (E).
Tighten the bleeder screw and screw on again. Then
tighten the pressure piping on the pressure piping
connection and connect it airtight.
Plug the pump.
Caution: When installing the suction and pressure
pipeline on appropriate connections, screw carefully
the given thread in a way to prevent damage as a result
of the pump body being torn!
Caution: Careful sealing (B) of the thread
connections and filling the suction system (suction
hose and pump body) with no air
(C) saves
unsuccessful suction attempts!
Check the foot valve (D) for tightness. Fill the system as
instructed (C) and take the suction hose out of the
transported media for inspection purposes before
putting the appliance into operation liquid must not
run out of the suction hose now!
Caution: Backwater may corrode in the pump body due
to the grey-iron-design pumps (brown colour)!
12
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gude HWW 1000 P INOX 06026 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gude HWW 1000 P INOX 06026 in the language / languages: English, German, Dutch, French, Italian as an attachment in your email.

The manual is 3,77 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info