If the pump is used for ponds, wells etc. and in corresponding
water equipments, the standards applicable in the countries where
the pump is used shall be unconditionally observed.
Electric pumps used outside (e.g. at the ponds etc.) shall be
furnished with rubber electric cable type H07RNF, according to
standard DIN 57282 or. DIN 57245.
When the pump is in operation, no people or animals are
allowed to stay or dive in the liquid being repumped (e.g.
in swimming pools, in cellars etc.).
The repumped liquid temperature shall not exceed +35 °C.
Should extension cables be used, they shall be made
exclusively of rubber, type H07RNF, according to standard
DIN 57282 or DIN 57245. The pump connected to the
electric network shall never be touched by a cable, never
lifted by holding the cable or transport by means of a cable.
The connecting socket shall always be in necessary
distance from water and moisture and the plug shall be
protected against moisture.
Before putting the pump into operation check if the electric
cable and/or the socket are not damaged.
Before performance of any works on the pump the plug
shall be pulled out of the socket..
If the pump is built-in in a gully, the gully shall be covered
with cover to ensure the safety of people walking there.
The pump shall never be installed in moist shifts
(danger of shortcut, damage caused by corrosion)!
For avoiding or prevention of possible damage (as e.g.
flooding the rooms etc.) due to faulty pump operation
(e.g. due failure or defects) the owner (user) shall take
reasonable safety measures (installation of alarm
equipment, a spare pump etc.)
In case of failure on the pump,. the repair shall be
performed exclusively by an authorized service
repairshop.Only original spare parts may be used.
We have to draw your attention to the fact that
according to the valid standards we cannot take
responsibility for below mentioned cases of possible
damage caused by our devices:
Unproper repairs performed by unauthorized service repair
shops;
Using pump for a different purpose or failing to observe its
use according to the provisions;
Overloading of the pump by long-term operation.
Protection against Thermal Overloading
A sensor is built into the engine that automatically switches off
the pump if a certain temperature has been exceeded, and/or
it switches the pump on after it has been cooled. This
increases the service life of the pump quadruptly, and
prevents burning of the electric engine.
Protection against Overloading /Thermoswitch of the Engine
The pump is furnished with an engine thermoswitch. If the
motor is overheated, the thermoswitch switches the pump
automatically off. The cooling period makes approx. 25
minutes, thenafter the pump will be automatically switched
on again. If the engine switch is on, it is necessary to find
and remove the cause (see also “Troubleshooting”). The
data here given cannot be considered as instructions for
“home made” repairs, because the repair works require
specific professional knowledge and skill.
Therefore you have to contact customer service if any
failure occurs.
It is unconditionally necessary to secure good air
supply in order to prevent overheating of the pump!
Do not install the pump in too tight shifts, do not cover
it with anything!
Operation
Pull out the network plug.
Filtermontage (Filter nicht im Lieferumfang enthalten!)
Montage (siehe Abb. E)
Flussrichtung beachten
Gewinde abdichten (siehe Abb. B)
Beim Auffüllen Entlüften (Abb. C/E)
Max. Druck 5 bar
Vor Frost schützen
Filter regelmäßig mit Bürste und klarem Wasser reinigen
Air pressure
Open the consumption valve, e.g. water main tap, so that the
water may be pressed out of the system.
Turn the protection lid on the bleeding valve in the down
direction (F).
Check the air pressure in the vessel with compressor and
device for tyre pumping.
The specified air pressure is 1,5 ± 0,3 bar.
Bleeding
Release the bleeding screw and let the possible closed air
escape. (Fig. A; pos. 2)
Water Bubbles
Release the screw for draining water bubbles so that the
pump may be drained (Fig. A; pos.11)
Vessel pressure
Switch off pressure set by the manufacturer is 3-4 bar after
completion of filling.
Setting pressure of the vessel (air) makes 1,5 ± 0,3 bar and it
should be regularly checked and modified (G).
Safety Instruction for Operator
Use the device only after you have carefully read Operating
Manual.
Observe all safety instructions mentioned in the Manual.
Behave responsibly against other persons.
Instruction Step-by-Step
Connect the suction pipeline that complies with the
outlet connecting pipe to the check valve (C)
(foot
valve). Tighten all
threading connections by sealing
band (B)
After filling up remove the bleeding screw . (Fig. A;
pos. 10) on the back side of the pump and on the
connecting line of pressure pipeline. (Fig. A; pos. 1
and 2) Fill the device up until the water exits from
the bleeding hole (E)
Make tight the bleeding screw and retight it again.
Then make tight the pressure pipeline and connect
it.
Connect the pump to the electric network.
Caution: When installing suction and pressure
pipeline on corresponding connection lines, the
corresponding thread shall always be tightened
carefully so that no damage occurs due to cracking of
the pump shell (A) !
Caution: Careful sealing of thread connections
(A/B) and airless
filling (E) of suction system – (suction
hose and pump shell) , will save you from trying to
perform suction that may often be unsuccessful!
Check the tightness of the foot valve (D) – Fill the
system according to the instruction (C) and pull the
12
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gude HWW 1000 IE at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gude HWW 1000 IE in the language / languages: English, German, Dutch, French, Italian as an attachment in your email.

The manual is 1,13 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info