Automatic float
The float will automatically put the pump into operation when
the liquid level goes up or down. If the float cable is extended
or shortened, based on its support point, it will switch the
pump on or off due to the minimum or maximum height
required. The float cable is fixed to the pump handle with a
suitable pressure holder. Please check whether the float is
moving freely at pump operation. The pump must always be
rinsed with clean water when used in very dirty water. The
switching on and off heights can differ.
Thermal fuse/engine protection circuit-breaker
The drowned pump is equipped with an engine protection
circuit-breaker. If the engine is overheated, the engine
protection circuit-breaker will automatically switch the pump
off. Cooling time is app. 25 minutes, the pump subsequently
switches on. If the engine protection circuit-breaker switches
on, it is absolutely necessary to identify the cause and
remove it (see also the “Failure searching“). The given data
cannot be used for “family style“ repairs as it requires specific
professional knowledge. You must contact the customer
service department at any failures.
Residual risks and protective measures
Electric residual risks:
Threat Description Protective measure(s)
Direct
electric
contact
Electric shock Safety switch against FI stray
current
Indirect
electric
contact
Electric shock
through
medium
Safety switch against FI stray
current
Disposal
Instructions for disposal arise from icons placed on the
appliance or its package. The description of individual
meanings can be found in the “Marking on appliance“.
Requirements for operating staff
The operating staff must carefully read the Operating
Instructions before using the appliance.
Qualification
Apart from the detailed instructions by a professional, no
special qualification is necessary for appliance using.
Minimum age
Persons over 16 years of age can only work on the appliance.
An exception includes youngsters trained in order to reach
knowledge under supervision of the trainer during
occupational education.
Training
Using the appliance only requires corresponding training by a
professional or the Operating Instructions. No special training
is necessary.
Technical data
GS 1101 PI
Voltage/Frequency 230 V / 50 Hz
Motor capacity P1 1100 W
Maximum delivered quantity 16000 l/h
Maximum head of delivery 9,5 m
Maximum immersion 8 m
Hose connection 1 ½ ’’
Protection class IPX8
Water temperature 35 °C
Granulation 35 mm
Max. suction 6,4 kg
Weight ca 94633
Transport and storage
At winter storing, it is necessary to make sure there is
no water in the appliance as the frost could damage the
appliance.
Safety instructions for first putting into operation
Attention: The pump must not run without fillings.
The user is responsible to third parties if pump (pumping
station, etc.) is used.
To be operated on connections with a safety switch
against stray current (RCD) only!
Before putting into operation, a competent electrician must
check whether electric safety devices are in place.
Electric connection to a socket.
Check the voltage. Technical data given on the type label
must correspond with electric network voltage.
If the pump is used in ponds, wells, etc. and appropriate pumping
stations, standards valid for pumps in the given country must
unconditionally be observed.
Electric pumps used outdoors (e.g. in ponds, etc.) must be
equipped with a H07RNF type rubber connecting cable,
according to DIN 57282 or DIN 57245 standards.
If the pump is in operation, neither people nor
animals can be present or plunged in the pumped
liquid (e.g. pools, cellars, etc.).
The temperature of the drained liquid must not exceed +35
°C. If an extension cable is used, it must solely be out of
rubber, H07RNF type, according to DIN 57282 or DIN
57245 standards.
Never touch, lift or carry with a cable a pump
connected to network (pic. E)
It is necessary to make sure the connecting socket was not
near water and humidity and the plug was protected against
humidity.
Before putting the pump into operation, check whether the
electric cable and/or socket are not damaged.
Before any work on the pump, pull the plug out of the
socket.
Instructions step by step
Connect the water hose to appropriate pump outlet (see
the Assembly and first putting into operation).
Fix the rope, chain, etc. to the pump handle and place it
to the right place.
Put the pump “sideways“ (pic. D) to the pumped medium.
Make sure the floating switch is in the operating position.
Plug in the pump.
Rinse the pump with clean water after work finishing.
Floating switch positions (pic. B + C)
The operating or shutdown point of the pump can be set
with various floating switch positions. In pic. B you can see
the float cable without any fixation change with full switch
radius. The figure 1 is the working position and figure 0 the
shutdown position.
Due to appropriate fixation of the float cable, possible on the
pump handle, the switch radius can be reduced when there
is no sufficient space or at a corresponding level control.
The figure 1 in pic. C is the working position and figure 0
the shutdown position.
9
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gude GS 1101 PI 94633 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gude GS 1101 PI 94633 in the language / languages: English, German, Dutch, French, Italian, Polish as an attachment in your email.

The manual is 2,28 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info