15
Read and understand the opera-
ting instructions before using the
appliance. Abide by all the safety
measures stated in the service manual. Act responsib-
ly toward third parties.
In case of any doubts about connection and operati-
on refer please to our customer center
Specied Conditions Of Use
The pump is solely used for drainage and for pum-
ping into and out of containers in the house, garden,
farm and agriculture and only for water.
Not observing general regulations in force and
instructions from this manual does not make the
manufacturer liable for damages.
Caution! During at sucking in the automatic
mode, the pump can switch on and o every moment
in case of small areas due to water owing back from
the pump body.
To drain ooded spaces and provide at suction,
the pump should therefore essentially work in the
continuous mode (see page 6 pic. 1) and should not
be left unattended.
Technical Data
Horizontal Suction Pump GFS 401 S
Art. No .................................................................................94627
Service connection ................................... 230V/ 50Hz
Motor output P1 ..................................................400 W
Max. immersion .........................................................7 m
Max. head of delivery ..............................................8 m
Max. delivered quantity .................................7000 l/h
Max. suction ............................................................1 mm
Minimum height for automatic switch-on 30 mm
Maximum suction ..........................................bis 1 mm
Max. Water temperature .......................................35°C
Hose connection
................................................... 1 ½“ IG
Degree of protection ............................................. IPX8
Weight ..........................................................................5 kg
The pump is not suited for long-run operation
(e.g. as a circulation pump in ponds or streams).
When used in this manner, its service life is curtailed
correspondingly. In these cases, then, use a time
switch to secure sucient idle periods between
cycles of operation.
Do not leave the pump unattended while in
operation in order to prevent subsequent
damages caused by eventual malfunctions. Make
sure to disconnect the device from the grid if you
do not plan on using it.
Do not use the pump for drinking water!
The pump must not be connected to the
existing water-supply network as a pressure-
boosting device.
Power tool description
1
| Sensor switch
2
| Suction foot
3
| Pump connection
4
| Pump connection angle
5
| Connecting branch for the hose fitted with check valve
6
| Handle
7
| Power supply cable
Requirements for operating sta
The operating sta must carefully read the Opera-
tingInstructions before using the appliance.
Qualication : Apart from the detailed instructions
by aprofessional, no special qualication is neces-
sary forappliance using.
Minimum age : Persons over 16 years of age can
only workon the appliance.An exception includes
youngsters trained in order to reachknowledge
under supervision of the trainer duringoccupational
education.
Training : Using the appliance only requires corre-
spondingtraining by a professional or the Operating
Instructions. Nospecial training is necessary.
The operator is responsible for accidents or risks to
third parties.
Observe to keep out of dangerous zone
ENGLISH
GB
IPX8
19


Need help? Post your question in this forum.

Forumrules
1

Forum

gude-gfs-401-s-94627

Reset search

  • I need to know outer dimensions of the pump
    Gude GFS 401 S 94627
    Thank
    Vladimir
    vladimir@vazda.cz Submitted on 21-10-2020 at 16:36

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gude GFS 401 S 94627 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gude GFS 401 S 94627 in the language / languages: English, German, Dutch, French, Italian as an attachment in your email.

The manual is 2,64 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info