Safety prevention means:
Touch protection at the device should prevent fire and
burns; no part of the protection can be taken off
permanently.
Full protection is not provided for children and ill
persons!
The heating device is equipped with a low-oxygen
safety device. If a higher concentration of carbon
dioxide (CO2) is detected in the room, the safety
device will automatically shut the appliance off. The
appliance cannot be turned back on until the room is
ventilated properly.
After use of the heating device, the cylinder valve
must be turned off!
Operation
After having read the general safety instructions and
the device-specific safety instructions and having
understood them, you can start operating the device.
Follow these instructions:
Installation of the gas cylinder:
The device uses a mixture of propane and butane
under pressure of 50 mbar.
To operate the device, a gas cylinder with liquid gas
of max. 11 kg of filling is necessary, the hose is pre-
installed.
Gas regulator must be selected and/or purchased first
of all, depending on the purpose of use.
Installation or change of cylinder with liquid gas must
be performed in non-flammable atmosphere.
When the device is not in use and during change
of the cylinder, the device valve must be turned
off.
After the first and before any subsequent putting into
operation and especially after each bottle change, a
leak test using foamy solution (e.g. soapy water) must
be carried out.
Tightness is proven when no bubbles appear.
It is strictly forbidden to check tightness by open
flame!
The cylinder must be placed in such a position so that
it is not in contact with the sheet metal of the burner
and the gas supply attached to it. The hose must not
touch (be in contact with) the hot back side of the
burner.
The device is supplied with a 40 cm long hose. The
hose must not be shortened or exchanged for a
longer one.
Inspect the condition of the hose regularly, at least
during each change of the cylinder.
In case of damage to the hose, it must be replaced
with a hose of the same construction, tested
according to DIN DVGVV.
Connection of the hose to the regulator must be done
with minimum of V4" left thread. The screw spanner
SW 17 is required for installation.
Twisting or distortion of the gas hose during the
installation of the hose and pressure regulator to the
liquid gas cylinder is not permissible.
Warning! The hose must not touch (be in contact
with) the hot back side of the burner!
Operation with pressure regulators other than those
prescribed above is prohibited.
Make sure the hose and regulator are changed after
5 years at the latest.
Connection of the liquid gas cylinder:
Take the protective cover of the valve off.
Take the covering nut from the attachment socket off
by turning (right).
Check the rubber seal in the cylinder valve (regulator
connection).
The regulator and the hose must be screwed on
tightly (left thread). No not use any tool or instrument.
Do not turn the regulator but the sleeve nut.
Check the tightness of the connection.
Change of the liquid gas cylinder:
Close the cylinder valve
Unscrew the regulator.
Screw the closing nut on the connecting tread (left
thread) – put the protective cover on.
Connect the new cylinder and check tightness.
Start up procedure / discontinuation or stopping procedure of
the catalytic stove:
Before operation, let the cylinder stand in a vertical
position for 1 hour if transported so the elements
more burdening to the environment may settle down
to the bottom of the cylinder.
Place the gas cylinder to the inner space of the
device (back side). Connect the gas cylinder as
described above.
Open the cylinder valve on the propane cylinder by
turning to the left.
Push the large setup button down and turn it to the
large flame symbol – start.
Push the piezo-ignition button several times, to light
the starting flame. When the starting flame is visible,
keep the setup button pushed for about 20 seconds,
heating up the thermal element. You can release the
setup button afterwards and the heating is turned on
to the highest level. If the starting flame goes off,
though, repeat the procedure.
The heating output can be lowered by pushing lightly
on the setup button and turning it to the medium or
minimum flame symbol. We recommend to wait for 10
minutes after starting the operation before changing
the heating output.
The catalytic gas plate is slightly hot only in the area
of the starting flame, but the full heating output is
spread over the whole catalytic plate.
The slight smoke (fresh paint) will dissipate after
heating up.
CAREFUL! Do not move when hot (transport).
The gas cylinder must not be turned during the
operation or shut down of heating device. The highest
danger of accident!
Shutting off of the catalytic gas heating device:
CLOSE THE GAS VALVE ON THE CYLINDER.
Servicing
Do you have any technical questions? A claim? Do you
need spare parts or the Operating Instructions?
You will be helped quickly and without needless
bureaucracy at our webpage www.guede.com in the
Service part. Please help us be able to assist you. To be
able to identify your appliance when claimed, we need to
know its serial No., order No. and year of production. All
these details can be found on the type label. Enter the
details below for future reference.
Serial No.:
Order No.:
Year of production:
Tel.: +49 (0) 79 04 / 700-360
Fax: +49 (0) 79 04 / 700-51999
E-Mail: support@ts.guede.com
12
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gude Blueflame 4200 B 85079 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gude Blueflame 4200 B 85079 in the language / languages: English, German, Dutch, French, Italian as an attachment in your email.

The manual is 3,14 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info