621180
16
Zoom out
Zoom in
Previous page
1/68
Next page
Fault Cause Remedy
A
Compressor does not start
after switching on
Pressure in the air receiver is higher than switch-
on pressure
Release the pressure from the air receiver so
that the pressure switch switches
automatically
Faulty feeding Have the power feeding checked by an
authorized
p
erson
Circuit breaker of the motor interrupts the power
feed
Faulty pressure switch Have the pressure switch replaced by
an authorized person
B Compressor shortly starts or
buzzes at the reach of the
switch-on pressure and then
switches off automatically
Electric cable is longer than permitted or is of too
small cross-section
Check the length and cross-section of
the electric cable
C
Compressor runs without stop
Suction filter is contaminated heavily Clean or replace the suction filter
Pneumatic tool has too high air consumption Check the air consumption of the pneumatic
tool; contact authorized reseller
Leak at the compressor Locate the leak, notify Güde service
Too much condensing water in air receiver Drain the condensing water
Leaky pneumatic piping Check the pneumatic piping, seal the leak
Mud-discharge valve is open or missing Close or insert it
D In operation the relief valve
switch releases the
pressurized air
Leaky relief valve Clean or replace the relief valve
E
After switch-off pressure is
reached the relief valve
under the pressure switch
releases the pressurized air
until the switch-on pressure
is reached
Insert of the non-return valve is leaky or
faulty
Clean or replace the insert of the non-return
valve
Non-return valve is damaged Replace the non-return valve
F
Compressor switches on
frequently
Too much condensation water in the air
receiver
Drain the condensation water
Compressor is overloaded
G
Safety valve blows off
Pressure in the air receiver is higher than set-up
switch-off pressure
Have the pressure switch readjusted
/replaced by an authorized person (Güde
Service)
Safety valve is faulty Replace the safety valve or contact Güde
Service
H
Compressor heats too much
Intake air is insufficient Make sure that sufficient intake and outlet of
the air is guaranteed (minimum distance from
a wall 40 cm)
Cooling ribs at the cylinder (cylinder head) are
dirty
Clean the cooling ribs at the cylinder (cylinder
head)
Too long period of use Switch off the compressor
I
The oil level rises without oil
being added
Condensation water accumulates in oil Compressor is overdesigned, notify the Güde
Service
High air humidity Replace the oil
J
Compressor is overheated and
it switches off
Compressor is overloaded Notify the Güde Service
Compressor is faulty Notify the Güde Service
Compressor has under voltage Notify the Güde Service
Ambient temperature 35°C Notify the Güde Service
16


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gude 400-10-50 N 50015 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gude 400-10-50 N 50015 in the language / languages: English, German, Dutch, French, Italian as an attachment in your email.

The manual is 1,57 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info