621514
15
Zoom out
Zoom in
Previous page
1/60
Next page
After each use
clean the air holes and mobile parts off dust.
Regularly
paint metal parts with oil (universal oil)
check whether all screws are tightened.
Regularly (once a month at least) release the condensed
fluid from the air jet; failing to observe this regulation may
lead to guarantee for rusting through expiry – apart from
that, the compressor is maintenance-free.
(The condensed fluid may be brown-coloured due to
surface layer from the air jet)
1. Pull the connector plug out of socket!
2. At low pressure in the air jet open the bleeder (9)
(max. of 1 bar) and completely empty the condensed
fluid (use a suitable container)
3. Close the valve.
Air filter
Sometimes it is necessary to clean the filter bed. For that purpose
remove the air filter cover screw and remove the foam filter. Wash
it in warm soap water solution. Let the foam filter dry and reinsert
it to its place. Now assemble the air filter cover again.
Fuse against overheating: (depending on model)
If the compressor is loaded by a technical defect or possibly also
by continuing operation, the power feed will be automatically
interrupted by a thermo-switch. If such situation occurs it is
advisable to disconnect the compressor from the mains and let it
cooled down for approx. 5 minutes. If the compressor does not
start after certain period of operation, let it cooled down for
additional 3 minutes.
Fault Cause Remedy
Pressure in the air receiver is higher than switch-on
pressure
Release the pressure from the air receiver so
that the pressure switch switches
automatically
Faulty feeding Have the power feeding checked by an
authorized person
Circuit breaker of the motor interrupts the power
feed
A
Compressor does not start after
switching on
Faulty pressure switch Have the pressure switch replaced by an
authorized person
B Compressor shortly starts or
buzzes at the reach of the
switch-on pressure and then
switches off automatically
Electric cable is longer than permitted or is of too
small cross-section
Check the length and cross-section of the
electric cable
Suction filter is contaminated heavily Clean or replace the suction filter
Pneumatic tool has too high air consumption Check the air consumption of the pneumatic
tool;
contact authorized reseller
Leak at the compressor Locate the leak, notify Güde service
Too much condensing water in air receiver Drain the condensing water
Leaky pneumatic piping Check the pneumatic piping, seal the leak
C
Compressor runs without stop
Mud-discharge valve is open or missing Close or insert it
D In operation the relief valve
under the pressure switch
releases the pressurized air
Leaky relief valve Clean or replace the relief valve
Insert of the non-return valve is leaky or faulty Clean or replace the insert of the non-return
valve
E
A
fter switch-off pressure is
reached the relief valve under
the pressure switch releases the
pressurized air until the switch-
on pressure is reached
Non-return valve is damaged Replace the non-return valve
15
15


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gude 231-8-24 6TLG 71095 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gude 231-8-24 6TLG 71095 in the language / languages: English, German, Dutch, French, Italian as an attachment in your email.

The manual is 1,01 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info