PX Version 5.0 - QX/RX Version 4.51 Installation Manual – Issue F
- 37 -
Proximity Reader
Proximity Reader
Access Module Connections
Max. 150m
Brown, LED green
+-AB
Engineer
Keypad
FS 1
FS 2
5 V
250 mA
8
1
ON OFF
+-AB
Black, 0 Volt
Orange, DATA 0/Clock
Blue, DATA 1/Data
Green, LED red
Red, V+ via FS1 (see LK 1)
Ground
Black, 0 Volt
Orange, DATA 0/Clock
Blue, DATA 1/Data
Green, LED red
Brown, LED green
Red, V+ via FS2 (see LK 1)
NVM1
NVM2
12 V
250 mA
Exit Reader
Entry Reader
Smart PSU
Interface
XiB
Comms
Case
Tamper
Reader supply voltage
- Select 12v for
Guardall readers.
The diagram shows a Guardall reader.
Other types of reader may be used.
Refer to the engineer programming
manual (System/card types) for details.
37


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Guardall PX at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Guardall PX in the language / languages: English as an attachment in your email.

The manual is 1,16 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Guardall PX

Guardall PX User Manual - English - 46 pages

Guardall PX Installation Guide - English - 46 pages

Guardall PX User Manual - English - 52 pages

Guardall PX Additional guide - Dutch - 42 pages

Guardall PX Additional guide - Dutch - 48 pages

Guardall PX Additional guide - Dutch - 52 pages

Guardall PX User Manual - Dutch - 31 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info