Specification
Reception range: Internal: 910 ... 2050 MHz, two signal inputs (A, B)
Receivable transmission signal:
9.75 GHz LNC: 10700 ... 11800 MHz
10.00 GHz LNC: 10910 ... 12050 MHz
LNC oscillator frequency: Settable: 9.75/10 GHz
Tuning system: Frequency synthesizer with direct frequency entry.
Forward in 10 MHz steps.
Reverse in 3 MHz steps.
0.5 MHz single steps for finetuning.
Frequency search system: ATS for horizontal and vertical polarization.
Programmes: 199 TV programmes, 99 radio programmes.
Last station memory: For TV and radio.
Sound IF: Direct frequency entry of 5.00 ... 9.77 MHz, in 10 kHz steps.
Audio deemphasis: For main carrier, Mono, and ton 1 selectable between J 17 and 50 µsec.
Stereo: Wegener Licence
Remote control: TP 720 SAT universal remote control handset.
Display: 4-digit 7-segment display and OSD (on-screen display).
3 LED's for the reception units A/B and the Timer.
Timer: For preprogramming 4 TV or radio programmes on the reception unit B.
Modulator: Frequency synthesizer: UHF C25 ... C60, C 36 is preset.
LNC power supply: 2 x 14/18 V, max. 350 mA, LNC voltage with superimposed 22 kHz switching signal selectable.
(The current consumption is not allowed to exceed the above value if a multiple switch is used).
Connections: 2 measuring pins for field strength indication (AGC) for precise aerial adjustment.
3 EURO-AV sockets (TV, decoder, video recorder) with full-automatic socket switching.
3 Cinch sockets (Audio L and R, remote control).
2 IEC coax sockets 75 Ω (terrerstrial aerial input and output).
2 IEC coax sockets 75 Ω (SAT aerial inputs "A" and "B").
Temperature range: Ambient temperature 0 ˚C ... + 40 ˚C according to VDE 0860
Mains voltage: 190 ... 264 V~, 50/60 Hz
Weight: approx. 2.1 kg
German Federal Post Office
certification: BZT KU 00705
This device is interference-suppressed in accordance with applicable European standards. It complies with the safety directive
VDE 0860 and thus with the international safety regulation IEC 65.
This device must only be operated with the mains cable set supplied. It prevents interferences from the mains and is an integral component
of the device. If a replacement is required, order only the mains cable set from a customer service with the designation GWN 9.22 / Subject
Number 8290.991-316.
Subject to alteration!