Technical Data
Reception range: intern: 910 ... 2050 MHz, two signal inputs (A, B)
Receivable transmission signals:
9.75 GHz LNC: 10700 ... 11800 MHz
10.00 GHz LNC: 10910 ... 12050 MHz
LNC oscillator frequency: settable: 9.75/10 GHz
Tuning system: Frequency synthesizer with direct frequency input.
Forward in 10 MHz increments
Reverse in 3 MHz increments
Single increments in 0.5 MHz increments, corresponds to fine tuning
Frequency search: ATS for horizontal and vertikal polarization
Programmes: 199 TV programmes, 99 radio programmes
Last Station Memory: For TV and Radio
Sound - IF: Direct frequency input of 5.00 ... 9.99 MHz, adjustable in 10 kHz increments
Audio deemphasis: Selectable for main sound, sound 1 between J17 and 50 µsec.
Stereo: Wegener Lizenz
Remote control: rc sat (rc 212 compatible); remote control can be operated on two levels;
(for simultaneous operation of 2 SAT receivers)
Display: 4-place, 7-segment display and OSD display for programme position number and timer menu.
3 LEDs for stereo, timer and radio
Timer: For switching a TV or radio programme on and off.
Modulator: Frequency synthesizer: UHF C25 ... C60, K 36 pretuned
LNC supply: 14/18 V, max. 500 mA, LNC voltage selectable with superimposed 22 kHz switching signal.
(The current consumption must not exceed this valuve if a Multi-switch is used)
If required, the LNC voltage can be switched off with switch
´E.
Connections: 4-way terminal strip, as connection for controlling a remote unit.
3 EURO-AV sockets (TV, decoder and video recorder) with automatic socket switchover
3 cinch sockets (NF-Audio L and R. and remote control)
2 IEC coax sockets 75 (Terr. -Aerial input and output)
2 IEC coax sockets 75 (SAT-Aerial input »A« and »B«)
Temperature rang: Ambient temperature range 0 ˚C ... + 40 ˚C in accordance with VDE 0860
Power supply: 220 ... 240 V~, 50/60 Hz
(Control range of power supply unit 190 ... 264 V)
Housing: (WxHxD) ca. 360x84x285 mm
Weight: approx. 2.1 kg
German Federal Post Office
certification: BZT KU 00705
This device is interference suppressed in accordance with applicable European standards. It complies with safety directive VDE 0860
and thus with the International safety regulation IEC 65.
This device must only be operated with the cable prevents disturbances emitted by the mains and is an integral component of the device. If
a replacement is required, order only the mains cable set from customer service with the designation GWN 9.22 / Number 8290.991-316.
Subject to change without notice
19


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Grundig STR 312 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Grundig STR 312 in the language / languages: English as an attachment in your email.

The manual is 0,43 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Grundig STR 312

Grundig STR 312 User Manual - German - 21 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info