Application
Thermostat mixers are designed for hot water supply via
pressurised storage heaters and, utilised in this way, provide
the best temperature accuracy. With sufficient power output
(from 18 kW or 250 kcal/min), electric or gas instantaneous
heaters are also suitable.
Thermostats cannot be used in conjunction with
non-pressurised storage heaters (displacement water
heaters).
All thermostats are adjusted in the factory at a flow pressure
of 3 bar on both sides.
Should temperature deviations occur on account of special
installation conditions, the thermostat must be adapted to local
conditions (see Adjusting).
Specifications
Minimum flow pressure 0.1 bar
Maximum operating pressure 10 bar
Test pressure 16 bar
If static pressure is greater than 5 bar, fit pressure reducer.
Avoid major pressure differences between cold and hot water
supply.
Maximum difference between cold- and hot water supply
pressure: 1: 5
Flow rate at 0.1 bar flow pressure without downstream
restrictor: approx. 5.5 l/min
Flow rate at 3 bar flow pressure: approx. 42 l/min
Temperature
-Hot water inlet (maximum): 80 °C
-Recommended (energy saving): 60 °C
-Safety stop: 38 °C
Water connection cold - right
hot - left
Minimum flow rate: = 5 l/min
Installation
Flush piping system prior and after installation of fitting
thoroughly (Consider EN 806)!
Install S-unions and screw-mount the mixer, see fold-out
page I, Fig. [1].
Refer to the dimensional drawings on fold-out page I.
The projection can be increased by 20mm with an extension,
see Replacement Parts, fold-out page II, Prod. no. 07 130.
For better fixing into dry-lined walls a mounting frame
can be used (see Replacement Parts, fold-out page II,
Prod. no.: 18 153).
Adjustment
Temperature adjustment, see Figs. [2] and [3].
1. Open the shut-off valve and check the temperature of the
water with a thermometer, see Fig. [2].
2. Lever out cap (A), see Fig. [3].
3. Remove screw (B).
4. Detach temperature control handle (C).
5. Turn regulating nut (D) until the water temperature has
reached 38 °C.
6. Install temperature control handle (C) so that button (E)
points towards the front, see Fig. [2].
7. Screw in screw (B), see Fig. [3].
8. Refit cap (A).
Temperature limitation
The safety stop limits the temperature range to 38 °C. The
38°C limit can be overridden by pressing the button (E).
Prevention of frost damage
When the domestic water system is drained, thermostat
mixers must be drained separately, since non-return valves
are installed in the hot and cold water connections. For this
purpose, the mixer must be removed from the wall.
Maintenance
Inspect and clean all parts, replace if necessary and lubricate
with special valve grease.
Shut off the hot and cold water supply.
I. Non-return valve (F), see fold-out page III, Fig. [4].
Remove connection nipple (G) by turning clockwise (left-
hand thread) using a 12mm allen key.
Install in reverse order.
II. Thermostatic compact cartridge (H), see fold-out page III,
Fig. [5].
Loosen screw ring (J) using a 34mm tool.
If necessary, lever out thermostatic compact cartridge (H)
via recess (H1).
Remove screw ring (J).
Install in reverse order.
Observe the correct installation position of the
thermostatic compact cartridge (H), see detail (H2).
Readjustment is necessary after every maintenance operation
on the thermostatic compact cartridge (see Adjusting).
III. Headpart (K), see fold-out page III, Fig. [6].
Replacement Parts, see fold-out pages II
( * = special accessories).
Care
For directions on the care of this fitting, refer to the
accompanying Care Instructions.
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Grohe Grohtherm 1000 Cosmopolitan at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Grohe Grohtherm 1000 Cosmopolitan in the language / languages: English as an attachment in your email.

The manual is 0,34 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Grohe Grohtherm 1000 Cosmopolitan

Grohe Grohtherm 1000 Cosmopolitan Installation Guide - All languages - 6 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info