Electrical test data
Software class A
Contamination class 2
Rated surge voltage 2500 V
Temperature of ball impact test 100 °C
The test for electromagnetic compatibility (interference
emission test) was performed at the rated voltage and rated
current.
Special accessories - The factory settings can be changed
and special functions can be activated, deactivated and set
using the infrared remote control (Prod. no. 36 407). The
current Technical Product Information for the remote control
can be downloaded from
www.grohe.com/tpi/remote-control.
Installation, see fold-out page II.
Flush pipes thoroughly before and after
installation (observe EN 806)!
Check connections for leaks and check function of
fitting.
Prevention of frost damage
When the domestic water system is drained, thermostats must be
drained separately, since non-return valves are installed in the hot
and cold water connections.
The complete thermostat assemblies and non-return valves must
be unscrewed and removed.
Adjustment
Before and after any maintenance operation on the
thermostatic compact cartridge the thermostat must be
adjusted.
Setting the temperature, see fold-out page II.
Operation, see fold-out page II.
Start water flow
Touch sensor system.
Stop water flow
• Touch sensor system
• Water flow stops after expiry of the set running time
Activating cleaning mode,
see fold-out page II.
Activating thermal disinfection,
see fold-out page III.
National standards must be observed.
1. Switch off fitting with App or remote control (Submenu
Service), see Fig. [1].
2. Unlock thermostat function with enclosed key,
see Fig. [2] - [4].
3. Start thermal disinfection with App or remote control
(Submenu Configuration), see Fig. [5].
4. Leave shower area.
The fitting starts the thermal disinfection.
If an object is in the detection zone, then the thermal
disinfection will be interrupted and the fitting is locked. The
thermal disinfection must be started again.
After the thermal disinfection the fitting is locked.
5. Restore thermostat function with enclosed key,
see Fig. [6] - [8].
6. After 15 minutes the fitting can be unlocked, see Fig. [9].
Making settings
Setting the running time, see fold-out page III.
Setting the programme, see fold-out page IV.
*A: Cleaning mode: The water flow can be temporarily
locked.
*B: Interval of automatic flushing, usage-independent.
*C: Interval of automatic flushing, usage-dependent.
*D: Runtime of automatic flushing.
*E: Runtime of thermal disinfection.
Maintenance, see fold-out page IV.
• Shut off hot and cold water supply.
• Disconnect voltage supply.
• Inspect and clean all parts, replace if necessary and
lubricate with special grease.
Thermostatic compact cartridge
Readjustment is necessary after each maintenance
operation on the thermostatic compact cartridge (see
Adjustment).
In order to ensure long-term protection from scalding, at
least once a year must be checked that the pre-adjusted
outlet temperature is not exceeded.
Replacement parts
see fold-out page I (* = special accessories)
Care
For directions on the care of this fitting, please refer to the
accompanying Care Instructions.
Disposal note
Caution, risk of scalding.
During the thermal disinfection do not go
in the shower area.
Caution, risk of scalding.
Necessarily restore thermostat function
to obtain pre-set temperature.
This category of device does not belong in the
domestic waste, but must be disposed of separately
in accordance with the relevant national regulations.
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Grohe 36415 EUROSMART COSMOPOLITAN E at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Grohe 36415 EUROSMART COSMOPOLITAN E in the language / languages: All languages as an attachment in your email.

The manual is 3,99 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info