759834
4
Zoom out
Zoom in
Previous page
1/10
Next page
1
English
Application
Operation is possible in conjunction with:
Pressurized storage heaters
Thermally controlled instantaneous heaters
Hydraulically controlled instantaneous heaters
Operation with low-pressure storage heaters (displacement water
heaters) is not possible.
Specifications
Max. flow 13.7 L/min or 3.6 gpm / 45psi
Flow pressure
- min. 7.25 psi
- recommended 14.5 - 72.5 psi
- greater than 72.5 psi, fit pressure reducing valve
Max. operating pressure 145 psi
Test pressure 232 psi
Temperature
- max. (hot water inlet) 176 °F
Water connection cold - Right hand
hot - Left hand
Notes:
- Installation of backflow protection must comply with local codes
and regulations.
- Major pressure differences between cold and hot water supply
should be avoided.
Installation
Refer to the dimensional drawing on fold-out page I.
Flush piping system prior and after installation of faucet
thoroughly!
Side valves
Valve with a groove on the top edge of the cartridge (A1) and in
addition marked with blue tape should be mounted on the right
(cold water) side, see fold-out page II, fig. [1].
Valve without a groove on the top edge of the cartridge (A1) and
in addition marked with red tape should be mounted on the left
(hot water) side.
1. Screw the mounting set (B) to the bottom of the thread of the side
valve (A). Make sure that the rubber washer (B1) is on the top of
the fiber washer (B2).
2. Insert the side valve (A) through the basin hole from below.
3. Slide on seals (C) and screw on nut (D). Make sure that the fiber
washer (C1) is on the top of the rubber washer (C2).
4. With 32mm open-ended spanner fasten the side valve (A). The
distance between the top of the headpart and the basin must
be 1 25/32", see fig. [2].
5. Screw the escutcheon (D1) down to the nut (D), see fig. [1].
Mount lever (18 077) not included in the scope of delivery, see
fig. [3].
- Push ring (A2) onto headpart (A1).
- Push on lever.
Install lever (18 085) not included in the scope of delivery.
- Push on lever complete and screw cap (F) onto
headpart (A1).
Vacuum breaker
1. Insert the vacuum breaker body with seal (G) and nut (G1)
through the basin hole from below, see fig. [4].
2. Slide on seal (G2) with ring (H) and screw on nut (I).The distance
from the top of the body to the bottom of the ring must be 2 3/16",
see fig. [6].
3. Secure vacuum breaker body to the basin by tightening
nut (G1), see fig. [4].
4. Slide on tube (J) and cover (K), see fig. [5].
5. Tighten the connection tee (L) to the vacuum breaker body with
connection nut (M).
Diverter
1. Insert diverter body with nut (N) and seals (O), (O1 or O2)
through the basin hole from below, see fig. [7].
2. Slide on seal (O3 or O4) and screw on nut (P) until it is at the
same height as the top of the diverter body (P1).
3. Secure diverter body to the basin by tightening nut (N) using
a 36mm open-ended spanner.
4. Screw on escutcheon (Q), see fold-out page III, fig. [8].
5. Press on snap insert (R) and secure with screw (R1).
6. Push on handle (S).
Verticle spray, see fig. [9].
1. Insert body with seals (T) from below.
2. Slide on seals (T1) and secure with nut (U) using a 22mm open-
ended spanner.
3. Jet-height can be decreased by turning the nozzle (V) to the left,
turning to the right increases jet-height.
4. Screw on spray face plate (W).
Fit pop-up drain (28 957), see fold-out page I, ensure that flange
of pop-up drain is sealed.
Connect wideset bidet, see figs. [10] and [11].
1. For this purpose the supply pipes must be installed on to the
angle stops (or other supply points).
2. The cold water supply should be connected on the right, the hot
water supply on the left side.
3. Connect both side valves to the connection tee via the flexible
hoses.
4. Connect the flexible hose from the vacuum breaker to the
diverter.
5. Connect the verticle spray to the bottom of the diverter.
Open cold and hot water supply and check connections for
leakage!
Maintenance
Inspect and clean all parts, replace as necessary and grease with
special grease (Prod. no. 18 012).
Shut off cold and hot water supply!
I. Replacing the headpart, see fig. [12].
1. Remove lever
Lever (18 077):
- Pull off lever.
- Pull off ring (A2).
Lever (18 085):
- Unscrew cap (F) and pull off lever complete.
2. Unscrew headpart (A1) using a 17mm socket wrench.
3. Change complete ceramic cartridge (A1) or O-ring (A3).
Observe the different replacement part numbers of the
headparts, see fold-out page I.
Observe the correct installation position!
II.Vacuum breaker, see fig. [13].
1. Pull off cover (K) and tube (J).
2. Remove circlip (X), pull out and replace double-ball vacuum
breaker (Z).
3. Loosen nut using a 21mm open-ended spanner and replace
check valve (08 565), see fold-out page I.
III.Vertical spray, see fig. [14].
Unscrew and clean spray face plate (W) and nozzle (V).
Assemble in reverse order.
Replacement parts, see fold-out page I ( * = special accessories).
Care
Instructions for care of this faucet will be found in the Limited
Warranty supplement.
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Grohe 24667 Talia at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Grohe 24667 Talia in the language / languages: English, French, Spanish as an attachment in your email.

The manual is 0,37 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info