708284
8
Zoom out
Zoom in
Previous page
1/147
Next page
English
8
WARNING
This equipment incorporates parts, such as snap switches,
receptacles, and the like that tend to produce arcs or sparks
and, therefore, when located in a garage, it should be in a room
or enclosure provided for the purpose, or should be 460 mm or
more above the oor.
WARNING
Do not attach any tools to the open end of the hose until start-
up has been completed. Attaching a tool prematurely could
result in accidental operation causing serious injury.
WARNING
Do not use in an environment that is dusty or otherwise
contaminated. Using the air compressor in this type of
environment may cause damage to the unit.
APPLICATIONS
Air compressors are utilized in a variety of air system
applications. Match hoses, connectors, air tools, and
accessories to the capabilities of the air compressor.
You may use this product for the purposes listed below:
• operating some air-powered tools
• operating air accessories such as air nozzles and
inators
• operates some air powered paint spraying products
TRANSPORTING THE AIR Compressor
To move the air compressor:
Ensure auto/off switch is in the off position (O) Grasp the
handle rmly with one hand.
AUTO/OFF
Turn the power switch to the auto position (I) to power the
compressor on. To turn the air compressor off, turn the power
switch to the off position (O).
NOTE: When the compressor is in the auto position (I), the air
compressor will automatically turn back on when the tank air
pressure drops below the preset pressure limit. It will also
shut off again when the max pressure is reached.
RESETTING THE AIR Compressor
When amperage into the air compressor exceeds the specied
amperage, the air compressor will automatically shut off.
1. Turn the air compressor off.
2. Allow unit to cool and to trigger reset.
NOTE: If the overload protector is actuated, the motor must be
allowed to cool down for 30 minutes.
3. Turn the air compressor on.
WARNING
Never exceed the pressure rating of the tool as recommended
by the manufacturer. When using this air compressor as an
ination device, always follow the maximum ination guidelines
stated by the manufacturer of the item being inated.
WARNING
Always ensure the switch is in the off position (O) and the
regulatory pressure gauge reads zero bar before changing air
tools or disconnecting the hose from the air outlet. Failure to do
so could result in possible serious personal injury.
CONNECTING/DISCONNECTING HOSES TO THE AIR
COMPRESSOR
When connecting a pneumatic air nailer or other air tool
always follow the manufacturer’s recommended start-up
procedure.
When connecting/disconnecting a hose to the air compressor
always do the following.
1. Ensure auto/off switch is in the off position (O)
2. Conrm that the outlet pressure is at zero bar by fully
turning the regulator knob counterclockwise to fully
reduce air pressure at the outlet.
NOTE: Turning the knob clockwise increases air
pressure at the outlet. Turning counterclockwise
reduces air pressure at the outlet.
3. Attach coiled air hose to coupler on the side of the air
compressor.
4.Turn power switch to the auto position (I).
5. Allow unit to reach max pressure as indicated on the
tank pressure gauge.
6. Set regulator to desired pressure by rotating pressure
regulator knob. The regulator pressure will appear on
the gauge marked as outlet.
To disconnect a coiled air hose:
1. Conrm that the outlet pressure is at zero bar.
2. When disconnecting a hose from quick coupler, always
rmly hold release end of hose.
3. Pull back on the release sleeve on the quick coupler.
4. With a rm grip, pull out the quick-connect air tting
that is attached to the quick coupler.
5. Attaching or disconnecting pneumatic tools from the
air compressor.
NOTE: Each tool is different. Refer to the instructions of
the manufacturer before operating a tool in the seated
position.
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Greenworks G24AC at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Greenworks G24AC in the language / languages: English, German, Dutch, Danish, French, Italian, Polish, Portuguese, Swedish, Spanish, Finnish as an attachment in your email.

The manual is 14 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info