627686
19
Zoom out
Zoom in
Previous page
1/184
Next page
DM-300 • DM-310 • DM-330 • DM-350
19
Accuracy
Refer to “Specifications” for operating conditions and temperature
coefficient.
Accuracy is specified as follows: ± (a percentage of the reading + a fixed
amount) at 23 °C ± 5 °C (73.4 °F ± 9 °F), 0% to 75% relative humidity.
True RMS readings: DM-300, DM-330, and DM-350 AC accuracies are
specified from 5% (10% for 600.0 mV range) to 100% of the range unless
otherwise specified. Frequency must be within the specified bandwidth for
non-sinusoidal waveforms. Crest factors are as follows:
Crest factor < 2:1 at full scale
Crest factor < 4:1 at half scale
DC Voltage
Range Accuracy
600.0 mV 0.7% + 0.2 mV
6.000 V 0.5% + 0.003 V
60.00 V 0.5% + 0.03 V
600.0 V 0.7% + 0.2 V
1000 V 1.2% + 6 V
Input Impedance: 1000 M
nominal for 600.0 mV range;
10 M nominal for all other
ranges
AC Voltage
Accuracy at
Range 50 Hz to 500 Hz
600.0 mV 1.2% + 0.3 mV
6.000 V 1.0% + 0.003 V
60.00 V 1.0% + 0.03 V
600.0 V 1.0% + 0.3 V
1000 V 2.5% + 6 V
Input Impedance: 10 M || 90 pF
nominal
Ohms
Range Accuracy
600.0 0.8% + 0.4
6.000 k 0.7% + 0.002 k
60.00 k 0.7% + 0.02 k
600.0 k 0.7% + 0.2 k
6.000 M 0.9% + 0.004 M
60.00 M 2.0% + 0.04 M
600 with Continuity Beeper
Range Accuracy
600.0 0.8% + 0.4
Continuity Beeper Response:
< 100 µs
Open Circuit Voltage:
0.4 VDC typical
Audible Threshold:
Between 10 and 150
Diode Tester
Open Circuit
Test Current Voltage Accuracy
0.4 mA typical < 1.6 VDC typical 1.9% + 0.003 V
19


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Greenlee DM-350 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Greenlee DM-350 in the language / languages: English, German, Dutch, French, Italian, Portuguese, Spanish as an attachment in your email.

The manual is 5,53 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info