627683
22
Zoom out
Zoom in
Previous page
1/184
Next page
22
Specifications
Display: 6000-count LCD (9999-count in frequency mode)
Polarity: Automatic
Sampling Rate: 5 per second
Temperature Coefficient: Nominal 0.15 x (specified accuracy) per °C
below 18 °C or above 28 °C
Automatic Power-Off: After 30 minutes of inactivity.
To disable this feature, press SELECT while turning the meter on.
Noise Rejection*:
Normal Mode Rejection Ratio > 30 dB at 50 Hz and 60 Hz when
measuring DCV
Common Mode Rejection Ratio > 60 dB from 0 Hz to 60 Hz when
measuring ACV
Common Mode Rejection Ratio > 90 dB at 0 Hz, 50 Hz and 60 Hz when
measuring DCV
Operating Conditions:
–10 °C to 31 °C (14 °F to 88 °F), 0% to 80% relative humidity (non-
condensing)
31 °C to 50 °C (88 °F to 122 °F), relative humidity decreasing linearly
from 80% to 50%
Altitude: 2000 m (6500') maximum
Indoor use only
Storage Conditions: –20 °C to 60 °C (–4 °F to 140 °F)
0% to 80% relative humidity (non-condensing)
Remove battery.
Pollution Degree: 2
Battery: 9-Volt (NEDA 1604, JIS 006P or IEC 6F22)
Overload Protections:
Terminal: 1050 V RMS for voltage functions; 600 VDC/V RMS
for all other functions
A Terminal: 15 A/600 V fuse, interrupting rating 100 kA, 13/32" x 1-1/2"
Measurement Categories:
Terminal: Category III, 1000 Volts ac and dc, and Category IV,
600 Volts ac and dc
A Terminal: Category IV, 600 Volts ac and 500 Volts dc
*Noise rejection is the ability to reject unwanted signals, or noise.
Normal mode voltages
are AC signals that can cause inaccurate DC
measurements. NMRR (Normal Mode Rejection Ratio) is a measure
of the ability to filter out these signals.
Common mode voltages
are signals present at the COM and + input
terminals, with respect to ground, that can cause digit rattle or offset
in voltage measurements. CMRR (Common Mode Rejection Ratio) is
a measure of the ability to filter out these signals.
22


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Greenlee DM-300 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Greenlee DM-300 in the language / languages: English, German, Dutch, French, Italian, Portuguese, Spanish as an attachment in your email.

The manual is 5,53 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info