Using the Features
Automatic Power Off To extend battery life, the meter will shut itself off
after approximately 30 minutes of inactivity. To restore power, press any
button. To disable this feature, press SELECT while turning the meter
on.
MAX MIN Press and hold to begin recording the input. “MAX MIN” will
appear on the display. The meter will beep whenever the minimum or
maximum is updated. When using the MAX MIN function, press
momentarily to cycle through the maximum, minimum, difference
(MAX – MIN). Press and hold to exit this mode.
The Automatic Power Off feature should be disabled for extended use of
MAX MIN recording.
•EFPress momentarily to detect the electric field that surrounds current-
carrying conductors. Signal strength is displayed as a series of dashes
on the display.
Use the tester’s built-in antenna (located along the top, near the
LCD) for tracing live circuits or locating a break in a wire.
For more precision, such as distinguishing between current-
carrying and ground wires, connect a test lead to the + input
terminal and use it as a probe.
(DM-350 only) Press and hold until LCD illuminates. The lamp
turns off after 90 seconds to extend battery life.
SELECT Press momentarily to toggle between functions, or to toggle
between AC and DC when measuring current.
RANGE Press once to enter the manual ranging mode. The
icon
will disappear from the display. Press repeatedly to step through the
ranges. Press and hold to return to the automatic ranging mode.
When using MAX MIN or HOLD, pressing
RANGE
will cause the meter to
exit that mode.
HOLD Press momentarily to hold the present value on the display.
Press again to exit this mode.
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Greenlee DM-300 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Greenlee DM-300 in the language / languages: English, German, Dutch, French, Italian, Portuguese, Spanish as an attachment in your email.

The manual is 5,53 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info