CLM-1000 • CLM-1000E
Using the Features
: Press momentarily to turn the backlight ON. Once
lit, press button again to turn the backlight OFF. The
backlight automatically turns OFF after approximately
30 seconds to extend battery life.
FT/M: Press momentarily to select length measurement
units. On the LCD, “ft” indicates feet and “m” indicates
meters.
CAL: The meter must be calibrated each time it is
turned ON. Refer to “Operation” for a complete descrip-
tion of the calibration process.
Esc: Press to escape from programming process.
MEM: Button is used for the user-selected program-
ming function. Refer to “Operation” for a complete
description of the programming process.
Cu/Al: Press momentarily to select cable material.
On the LCD, “Cu” indicates copper and “Al” indicates
aluminum.
HOLD: Press momentarily to enter data hold mode.
When button is pressed, “dH” is present on the LCD and
the current value is captured. To exit this mode, press
the HOLD, FT/M or Cu/Al button. “dH” is no longer
present on the LCD.
Auto Power Off (APO): When enabled, the meter will
automatically turn OFF after 10 minutes of inactiv-
ity. Inactivity is defined as no button press or rotary
switch movement. The buzzer sounds three times
approximately 30 seconds before the meter turns OFF
as a warning. To disable APO, press and hold the HOLD
button while turning the meter ON.
qp: Used during the user-selected programming
process. Refer to “Operation” for a complete description
of the programming process.
Programmable Switch Positions User’s Table
Use this table to keep track of the cable size that has been programmed into a switch position.
Makeannotations with something erasable because switch positions can be reprogrammed.
Switch
Position
Gauge
Material Type
Size Type (circle)
1 mm
2
AWG kcmil aught Cu or Al
2 mm
2
AWG kcmil aught Cu or Al
3 mm
2
AWG kcmil aught Cu or Al
4 mm
2
AWG kcmil aught Cu or Al
5 mm
2
AWG kcmil aught Cu or Al
6 mm
2
AWG kcmil aught Cu or Al
7 mm
2
AWG kcmil aught Cu or Al
8 mm
2
AWG kcmil aught Cu or Al
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Greenlee CLM-1000E at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Greenlee CLM-1000E in the language / languages: German, French, Spanish as an attachment in your email.

The manual is 2,61 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info