Assembly/Installation
GB
Lift the adjusting knob with a suitable tool
Release the fastening screw
Remove the upper part of the case
Determine the appropriate type of installation
5
The unit must be connected by a qualified person exercising
due care
Switch off the heating system before assembly
Check and make sure that the connecting wires are not
live
Guide the connecting wires through the opening in the unit’s base
Mount the base on a flat, firm surface or flush-mounted socket
Strip the connection wires properly and connect as shown in
the circuit diagram, see the circuit diagrams on the following
pages
Accuracy of control is only achieved if the stated current
values are adhered to.
Do you know how much current is drawn by the consumer?
If in doubt, check!
Select the right type of connection terminals when making the
connection!
6
7
8
Connection/Operation
GB
Technical data
GB
Determine the temperature range
thermio 102
a)
b)
c)
d)
thermio 402 thermio 103 thermio 403 thermio 513
––
Connect terminal 3 Connect terminal 3
LED OFF =
Comfort temperature
LED ON =
Lower temperature
––
Set temperature value
Connection of a time switch
2 =
Comfort temperature
1 =
Lower temperature
1=
Heating ON
0=
Heating OFF
1=
Heating ON
0=
Heating OFF
Put the setting knob on the shaf. Note the markings!
thermio 102
75 x 71 x 21
2-wire
approx. 200 mW
0,5/5 A/250 V~
0,5/4 A/250 V~
0,5/1 A/24 V–
Opens (with increasing temperature)
Ag Ni
T 30
II after suitable installation
Surface mounting
Screw terminal with wire fuse
+5 °C to +30 °C
approx. 1 K
Thermal
-20 °C to +70 °C
IP 20
as per EN 55014
Dimensions H x W x D mm
Weight g (approx.)
Connection
Power consumption
Switching capacity
- with ohmic load
-
with inductive load cos. ϕ 0,6
- minimum
Switching output
Switching contact
Ambient temperature
Protection class
Switching status indication
- thermostat
- selector switch
Type of installation
Type of connection
Day temperature regulation range
Overnight temperature drop
Temperature switching differential
Feedback
Storage temperature
Type of protection
Radio interference suppression
thermio 402
75 x 71 x 21
2-wire
approx. 200 mW
0,5/5 A/250 V~
0,5/4 A/250 V~
0,5/1 A/24 V–
Opens (with increasing temperature)
Ag Ni
T 30
II after suitable installation
yes
Heating On/Off
Surface mounting
Screw terminal with wire fuse
+5 °C to +30 °C
approx. 1 K
Thermal
-20 °C to +70 °C
IP 20
as per EN 55014
thermio 103
75 x 71 x 21
3-wire
approx. 200 mW
10 A/250 V~
4 A/250 V~
0,1 A/230 V–
Opens (with increasing temperature)
Ag Ni
T 30
II after suitable installation
Surface mounting
Screw terminal with wire fuse
+5 °C to +30 °C
approx. 4 K
approx. 0,5 K
Thermal
-20 °C to +70 °C
IP 20
as per EN 55014
thermio 403
75 x 71 x 21
3-wire
approx. 200 mW
10 A/250 V~
4 A/250 V~
0,1 A/230 V–
Opens (with increasing temperature)
Ag Ni
T 30
II after suitable installation
yes
Heating On/Off
Surface mounting
Screw terminal with wire fuse
+5 °C to +30 °C
approx. 0,5 K
Thermal
-20 °C to +70 °C
IP 20
as per EN 55014
thermio 513
75 x 71 x 21
3-wire
approx. 200 mW
10 A/250 V~
4 A/250 V~
0,1 A/230 V–
Opens (with increasing temperature)
Ag Ni
T 30
II after suitable installation
yes
LED green
Overnight temperature drop On/Off
Surface mounting
Screw terminal with wire fuse
+5 °C to +30 °C
approx. 4 K
approx. 0,5 K
Thermal
-20 °C to +70 °C
IP 20
as per EN 55014
Lower temperature O
N
Set the room temperature
e. g. 22°C
=
^
18°C
Lower temperature OFF
Set the room temperature
e. g. 22°C
=
^
22°C
ON
OFF
Lower temperature O
N
Set the room temperature
e. g.22 °C
LED ON +
=
^
18°C
Lower temperature OFF
Set the room temperature
e. g.22 °C
LED OFF +
=
^
22°C
LED OFF +
=
^
22°C
ON
OFF
ON
* Lower temperature = Comfort temperature minus 4 K (Kelvin)
3


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Grasslin Thermio 402 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Grasslin Thermio 402 in the language / languages: English, German, Dutch, French, Italian, Polish, Spanish as an attachment in your email.

The manual is 2,42 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info