14
Programming the Device Using a USB Cable
The device needs no power supply connection during the programming procedure as the power is supplied directly
by the USB connection. The device may therefore be programmed before installing it in the control panel.
NOTE: the relay cannot change status if the main power supply is not present.
Start the programming software.
Connect the USB cable to the PC and the device.
The device needs no installation driver as it is recognized automatically by Windows: this feature makes it easier to
reprogram the device, where necessary, in the future.
If the device is not recognized and the network LED continues to blink red, see the troubleshooting section.
The programming software of telltask 1C1 is clear, simple and self-explanatory. The sections that follow provide a
detailed description of each of the functions in the order in which they are displayed by the program.
Functions
System Password
In order to ensure the security of the system, the device prompts the operator to enter a password of four digits
(and/or characters, in PC mode only) indispensable to be able to send command SMS messages. The default pass-
word is four zeros (0000). For instructions on how to send command SMS messages, see the corresponding section.
List of Administrator Users
This list is made up of the telephone numbers of the users authorized to receive the alarm and/or notification SMS
messages and to control the device using quick commands (see corresponding section).
Temperature Sensor
The device has an internal sensor that can detect the ambient temperature. For default settings, the sensor is disa-
bled. The user may choose between the following operating modes (TMODE):
sensor disabled
sensor enabled
Calibration
It is possible to calibrate the temperature measured by probe (see: commands sms).
Note: It is recommended to calibrate the sensor after about 30 minutes of running, so the device has reached oper-
ating temperature
Room Thermostat Function
It allows you to control the relay output according to the ambient temperature measured by the temperature probe.
When connected to a heating or air-conditioning system, this device enables the temperature of a room to be con-
trolled by monitoring both the comfort temperature Th (heat temperature), the AUTOMATIC function, where present,
and the maintenance temperature Tf (frost temperature), the ANTIFREEZE function.
The temperature thresholds may be set either using the software or from a remote location by means of command
sms (see the Commands section).
The device also has a notification function (Notify SMS), which, when activated, enables the device to inform its
administrator users through an SMS if the room temperature drops 1°C below the frost temperature (Tf), sent repeat-
edly every 15 minutes until it is disabled by the user.
15
Alarm Input
The device has an alarm input, which allows you to send a text message to, both opening and closing of each contact,
administrative users
The text associated with each event may be customized from the software or through a command SMS.
This function informs the user of specific events that take place on the system or plant to which the device is con-
nected such as a boiler breakdown or voltage drop, the opening of a valve, etc..
Phone Ring Function
The device can store a list of telephone numbers and names (up to three hundred) authorized to activate and/or
deactivate the relay output simply by a telephone ring and thus with no cost whatsoever. The device recognizes the
incoming call, cuts if off immediately and activates the plant to which it is connected.
This function (RMODE) may be set in the following modes:
function disabled;
SWITCH mode: the relay is simply toggled ON and OFF; (this mode permanently disables the thermostat func-
tion);
PULSE mode: a programmable pulse of one to twenty seconds is emitted (this mode permanently disables the
thermostat function);
AUTOMATIC mode: used to activate the automatic room thermostat function (providing the temperature sensor
has been activated).
The user may also choose to activate the sms feedback option, which sends an SMS confirming the status of the
plant back to the mobile phone from which the telephone ring was received.
PULSE mode also enables the text of the SMS confirming the command executed to be customized.
Credit Function
This is an innovative function for rechargeable SIM cards that informs the user at a remote location of the residual
credit on the SIM card to which the device is connected.
As each telephone company adopts a different method of indicating the residual credit to users, this function may be
set in one of the following three modes most commonly used by telephone operators:
Using a quick command;
By calling a number to receive an SMS indicating the credit;
By means of a free SMS with a command for receiving the credit indication.
To find out the specific parameters to be entered, we recommend you consult your telephone company.
This function is not fully guaranteed as the telephone companies not only adopt different methods to indicate the
residual credit to users but they also change these methods continually.
Interfaces
GSM LED: GSM Signal Level
This LED identifies the level of the GSM signal. Its operation is described in the table below:
LED colour
Description
RED
The device is receiving no signal and/or is not registered on the network
FLASHING RED
Error situation: see the troubleshooting section
FLASHING GREEN
The number of flashes identifies the level of GSM field: it may range from 1 to 5.
GREEN The device is receiving or sending an SMS
STATUS LED: Status of the Relay Output
See the section below.
15


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Grasslin Telltask 1C1 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Grasslin Telltask 1C1 in the language / languages: English, German, French, Italian, Spanish as an attachment in your email.

The manual is 2,84 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info