Outgoing Call
without
Registration
Default is No. If set to “Yes,” user can place outgoing calls even when not registered (if
allowed by Internet Telephone Service Provider) but is unable to receive incoming calls.
Any port, member of a Hunting Group that is not registered with a SIP account, will be able to
place outbound calls using the SIP credentials of the primary Hunting Group port.
For example:
Port 1, 3 and 5 are members of the same Hunting Group. Port 1 is registered
with a SIP account. Ports 3 and 5 are not registered. Ports 3 and 5 will be able to place
outbound calls using the SIP account of port 1, even if Outgoing Call without Registration
is set to No
Register
Expiration
Allows the user to specify the time frequency (in minutes) for the GXW42XX to refresh its
registration with the specified registrar. The default interval is 60 minutes (or 1 hour). The
maximum interval is 65535 minutes (about 45 days).
SIP Registration
Failure Retry Wait
Time
Allows the user to specify the time frequency (in seconds) for the GXW42XX to re-register
after registration failure. The default interval is 20 seconds. The maximum interval is 3600
seconds (1 hour).
Local SIP port
Defines the local SIP port the GXW42XX will listen and transmit. The default value for Profile
1 is 5060 and 6060 for Profile 2.
Use random SIP
port
Default is No. If set to Yes, the device will pick randomly-generated SIP port. This is
usually necessary when multiple Gateway or ATA are behind the same NAT.
Refer to Use
Target Contact
Default is No. If set to YES, then for Attended Transfer, the “Refer-To” header uses the
transferred target’s Contact header information.
Transfer on
Conference
Hang up
Default is No
. In which case if conference originator hangs up the conference will be
terminated. When option YES is chosen, originator will transfer other parties to each other so
that B and C can choose either to continue the conversation or hang up.
Disable Bellcore
Style 3-Way
Conference
Default is No. you can make a Conference by pressing ‘Flash’ key. If set to Yes
, you need to
dial *23 + second callee number.
Remove OBP
from Route
Header:
Default is No. If set to Yes, the Outbound Proxy will be removed from the route header.
Support SIP
Instance ID
Default is Yes
. If set to Yes, the contact header in REGISTER request will contain SIP
Instance ID as defined in IETF SIP Outbound draft.
40


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Grandstream GXW4248 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Grandstream GXW4248 in the language / languages: English as an attachment in your email.

The manual is 0,78 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info