VIDEO SURVEILLANCE
The GXW410x can be used with an Analog Surveillance CCD Camera to perform video surveillance
function. This application should be used in a LAN environment or when both sides have public IP
address.
NOTE: The following information is essential, only if your GXW410x's hardware (Revision 1) has a
Video-IN Port, otherwise It will not show this functions.
VIDEO SURVEILLANCE PROCEDURES
Gateway side:
1. In the ADVANCED SETTING page, find the following field and change from default
setting NO to YES, reboot the device.
2. Connect an analog based surveillance camera to the VIDEOIN connection at the back
panel of the unit.
PC side (Monitor Device):
1. Download VLC from http://www.videolan.org/vlc/. This is the only player so far that
supports RFC 3984.
2. Launch VLC.
3. Go to Preferences->Input/Codecs->Demuxers->H264, check “Advanced options” in the
bottom. The option “Frames per Second” will show. Change that value to 5 and then save.
4. Go to Preferences->Input/Codecs->Access modules->Real RTSP, check “Advanced
options” in the bottom. The option “Caching value (ms) will show. Change that value to 1000
and then save. You may change it to a smaller value to reduce the delay.
5. If the viewer is under NAT, go to Preferences->Demuxers->Access modules-
>RTP/RTSP, check “Advanced options” in the bottom. The option “Use RTP over RTSP
(TCP)” will show. Check that option box. (Grandstream does NOT recommend this network
environment)
6. Close the Preferences window and go to File->Open Network Stream:
a) Select RTSP as the protocol
b) Enter the URL in the format of rtsp://admin:
ADMIN_PASSWORD@DEVICE_IP_ADDRESS:DEVICE_RTSP_PORT.
Change the blue text according to your configuration:
ADMIN_PASSWORD is the device’s web configuration password for admin.
DEVICE_IP_ADDRESS is the device IP.
DEVICE_RTSP_PORT is the RTSP port setting of the device.
If the port uses default value 554, the port portion can be omitted from the URL
c) Click OK to start the video.
29


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Grandstream GXW410x series at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Grandstream GXW410x series in the language / languages: English as an attachment in your email.

The manual is 0,8 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info