571664
19
Zoom out
Zoom in
Previous page
1/40
Next page
Gossen Foto- und Lichtmesstechnik GmbH
19
5.5 Averaging value AVR in the t and EV
functions Reflected light measuring
through the viewfinder
- The first measurement is to be taken with the
measuring button M.
- With the average measuring button AVR you can
measure up to 8 further contrast spots.
The single measuring values are displayed on the
analogue scale (identical measuring values are only
displayed once, but are taken into consideration when
the averaqe is calculated). After each measurement
with AVR, the average of all previous measuring
values is displayed. The average AVR appears on
the left digital display: f or EV with f-numbers in 1/10
increments and flashing on the analogue scale,
rounded to 1/2 stop increments. In the middle of the
display, the number of measurements M is displayed
(4 measurements in the example).
Incident light
with flat or spherical dome
Correspondingly, you can determine the average value
of the illumination of the various lights with the above
mentioned procedure. To do this, you can measure for
example your main, fill-in and background light
individually in the Studio.
19


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gossen STARLITE 2 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gossen STARLITE 2 in the language / languages: English as an attachment in your email.

The manual is 0,83 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Gossen STARLITE 2

Gossen STARLITE 2 User Manual - German - 40 pages

Gossen STARLITE 2 User Manual - French - 40 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info