571678
10
Zoom out
Zoom in
Previous page
1/72
Next page
10 GMC-I Messtechnik GmbH
Meanings of Symbols on the Instrument
The symbols on the instrument have the following meanings:
Warning regarding dangerous electrical voltage
Warning concerning a point of danger
(Attention: observe documentation!)
Test socket
Mark of approval from VDE test authority
Indicates EC conformity
This device may not be disposed of with the trash. For further
details on the WEEE marking, please refer to our website
www.gossenmetrawatt.com and enter search term ’WEEE’.
2.1 Notes Regarding the High-Voltage Test
(only Feature F02 or SECUTEST SIII+H)
The KS13 cable set, or similar cable sets, may not be used for the high-voltage
test. The high-voltage test may only be performed directly via the test socket!
Attention!
!
Do not hold the device under test in your hand during testing,
especially when testing safety class II devices.
Make sure that the device under test does not make contact
with any equipment or persons during testing.
Liability Exclusion
In the event of sparkover, PCs operated in proximity to the test instrument may
“crash” resulting in data loss. All data and programs should be suitably backed up
before high-voltage testing is performed, and computers should be shut down if
necessary. A crash may occur even if no RS 232 connection has been established.
The manufacturer of the test instrument assumes no liability for direct or
consequential damage to computers, peripherals or data which occurs
during high-voltage testing.
The manufacturer assumes no liability for defects at the device under test
which result from high-voltage testing. As a rule, defects can only occur at
devices under test which are not in compliance with applicable standards,
which were previously damaged or which have been improperly repaired,
because high-voltage testing is required for type and routine testing by
IEC 61010-1/EN 61010-1 / VDE 0411, part 1, as well as EN 60335,
EN 60601 and EN 60950.
!
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gossen Metrawatt SECUTEST SIII at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gossen Metrawatt SECUTEST SIII in the language / languages: English as an attachment in your email.

The manual is 0,82 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info