590771
146
Zoom out
Zoom in
Previous page
1/160
Next page
146 GMC-I Messtechnik GmbH
Appendix
10.6 Abbreviations
B, BF, CF
Classifications for application parts (chapter 10.5.2)
BetrSichV German occupational safety law
BGV German trade association regulation
BildscharbV German regulation regarding work at monitor
screens
CF card Compact flash memory card
DIN German Institute for Standardization
R PE
Differential protective conductor resistance, see page 45
E Electrical energy (during function test)
ElektroG German law for electrical and electronic equip-
ment: regulates distribution, return and environ-
mental disposal of electrical/electronic equipment
EN European standard
f Line frequency (during function test)
fp Test frequency
GUV Accident insurance required by German law
GUV-I (GUV information)
GUV-R GUV rules
GUV-V GUV regulations
I T Touch current
I PE Protective leakage current, Protective conductor
current
I EA Equivalent leakage current
equivalent device leakage current,
equivalent contact current,
equivalent leakage current
I E Equipment leakage current
I P Patient leakage current
I AP Applied Parts leakage current
IT system The IT system has no direct contact between
active conductors and grounded parts: bodies
within the electrical system are grounded.
I L Load current (during function test)
Ip Protective conductor test current during R PE mea-
surement, otherwise selection of AC or DC test cur-
rent
L Phase conductor
PF Power factor (during function test)
MedGV German medical device ordinance
MPG German medical product law
MSELV Medical safety extra-low voltage
N Neutral conductor
P Active power (during function test)
Pd Test socket
PE Ground potential, protective conductor
R INS Insulation resistance
RoHS
Directive regarding the restriction of use of hazardous
materials in electrical and electronic equipment
R PE Protective conductor resistance
S Apparent power (during function test)
SELV Safety extra-low voltage
U
REF
Reference voltage to which all leakage voltages
make reference (as a rule nominal line voltage)
U ISO Test voltage for insulation measurement
U LN Line voltage (during function test)
146


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gossen Metrawatt SECUSTAR FM at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gossen Metrawatt SECUSTAR FM in the language / languages: English as an attachment in your email.

The manual is 1,75 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info